Set up sensors to monitor selected properties of parts and assemblies and alert you when values deviate from the limits you specify.
To create a sensor, right-click the Sensors folder in the FeatureManager design tree, select Add Sensor, and set parameters in the PropertyManager.
Sensor Type
Simulation Data |
Defines locations for measuring result quantities in simulations. For more information about using sensors in simulations, see SolidWorks Simulation Help: Sensors. |
Mass Properties |
Monitors properties such as Mass, Volume, and Surface Area. |
Dimension |
Monitors dimensions you select. |
Interference Detection |
(Available in assemblies only.) Monitors the assembly for interferences between components you select. |
Proximity |
(Available in assemblies only.) Monitors the assembly for interferences between a line you define and components you select. |
Properties
Properties vary depending on the sensor type.
For
Mass Properties sensors:
|
Mass Properties |
Select a mass properties type:
- Mass
- Volume
- Surface Area
- Center of Mass X
- Center of Mass Y
- Center of Mass Z
|
|
Entities to Monitor |
Lists the entities you want to monitor, which you select in the graphics area. Entities can include parts, solid bodies, assemblies, or components. |
|
Value |
Lists the current value of the property. |
For
Dimension sensors:
|
Dimension to Monitor |
Lists the entities you want to monitor, which you select in the graphics area. |
|
Value |
Lists the current value of the dimension. |
For
Interference Detection sensors:
|
Components to Check |
Lists the entities you want to monitor, which you select in the graphics area. Entities can include components or the entire assembly. |
|
Value |
Indicates whether or not interferences are detected between the selected entities. |
|
Treat coincidence as interference |
Reports coincident entities as interferences. |
|
Show ignored interferences |
When selected, shows ignored interferences in gray under
Results
in the Interference Detection PropertyManager. When this option is cleared, ignored
interferences are not listed.
|
|
Treat subassemblies as components |
When selected, sub-assemblies are treated as single components, so
interferences between a sub-assembly's components are not reported. |
|
Include multibody part interferences |
Reports interferences between bodies within multibody
parts. |
|
Create fasteners folder |
Segregates interferences between fasteners (such as a nut and bolt)
into a separate folder under
Results in
the Interference Detection PropertyManager. |
Alert
Alerts notify you immediately when the sensor value deviates from the limits you specify. When a sensor triggers an alert, the sensor is flagged in the FeatureManager design tree. Select Alert and set an operator and limits.
For sensors with numeric values, specify an operator and one or two numeric values. Operators include:
- is greater than
- is less than
- is exactly
- is not greater than
- is not less than
- is not exactly
- is between
- is not between
For
Interference Detection sensors, specify:
is true |
Triggers an alert when interference is detected. |
is false |
Triggers an alert when no interference is detected. |