Hide Table of Contents

Mesh PropertyManager

The Mesh PropertyManager lets you mesh models for solid, shell, and mixed mesh studies. Beam studies do not use this PropertyManager.

To display the Mesh PropertyManager, open a part or assembly, click the down arrow on Run (Simulation CommandManager) and select Create Mesh .

Mesh Density

Mesh Factor Use a slider to change the global element size and tolerance. The leftmost position (Coarse) sets the global element size to twice the default. The rightmost position (Fine) sets the global element size to half the default.
  Reset Resets the slider to the default settings.

Mesh Parameters

Sets the global element size, tolerance, and options.

  Standard mesh Activates the Voronoi-Delaunay meshing scheme for subsequent meshing operations.
  Curvature based mesh Activates the curvature-based meshing scheme for subsequent meshing operations. The mesher creates more elements in higher-curvature areas automatically (without need for mesh control).
Unit Sets units for mesh sizes and tolerance.
Global Size Available for standard mesh only. Sets the global average element size. The software suggests a default value based on the model volume and surface area.
Tolerance Available for standard mesh only. Sets the tolerance value. The default tolerance is 5% of the global element size. If the distance between two nodes is smaller than this value, the nodes are merged unless otherwise specified by contact conditions. The tolerance cannot exceed 30% of the element size.
Adjusting the tolerance can help resolve some meshing problems. For example, if meshing fails due to free edges, increasing the tolerance can solve the problem.
  Automatic transition Available for standard mesh only. When checked, the program automatically applies mesh controls to small features, holes, fillets, and other fine details of your model. Clear Automatic transition before meshing large models with many small features and details to avoid generating large numbers of elements. See example below.
Maximum element size Available for curvature based mesh only. The maximum element size is used for boundaries with lowest curvature.
Minimum element size Available for curvature based mesh only. The minimum element size is used for boundaries with highest curvature.
Min number of elements in a circle Available for curvature based mesh only. Specifies the number of elements in a circle. To observe the effects of this option, the computed element size must be between the Maximum element size and Minimum element size. See How Element Size is Determined.
Element size growth ratio Available for curvature based mesh only. Specifies the global element size growth ratio starting from regions of high curvatures in all directions.

Advanced

  Jacobian points Available for high quality mesh only. Sets the number of integration points to be used in checking the distortion level of tetrahedral elements. You can base the Jacobian check on 4, 16, 29 Gaussian points or At Nodes.
  Draft Quality Mesh Specifies 4 corner nodes for each solid element and 3 corner nodes for each shell element. Draft quality mesh is recommended for quick evaluation and the default high quality option for final results.
  Automatic Trials for Solid Available for standard mesh only. Specifies that the mesher remeshes the model automatically using a smaller global element size. The ratio by which the global element size and tolerance are reduced for each trial is 0.8.
  Number of trials Sets the maximum number of mesh trials.
  Remesh failed parts with incompatible mesh Specifies that the incompatible meshing be used for bonded bodies that fail compatible meshing. Used for solid mesh only.

Options

  Save settings without meshing Saves mesh options.
  Run (solve) the analysis Runs the study right after meshing.

Example of Automatic Transition

Mesh with Automatic transition cleared Mesh with Automatic transition checked


Provide feedback on this topic

SOLIDWORKS welcomes your feedback concerning the presentation, accuracy, and thoroughness of the documentation. Use the form below to send your comments and suggestions about this topic directly to our documentation team. The documentation team cannot answer technical support questions. Click here for information about technical support.

* Required

 
*Email:  
Subject:   Feedback on Help Topics
Page:   Mesh PropertyManager
*Comment:  
*   I acknowledge I have read and I hereby accept the privacy policy under which my Personal Data will be used by Dassault Systèmes

Print Topic

Select the scope of content to print:

x

We have detected you are using a browser version older than Internet Explorer 7. For optimized display, we suggest upgrading your browser to Internet Explorer 7 or newer.

 Never show this message again
x

Web Help Content Version: SOLIDWORKS 2011 SP05

To disable Web help from within SOLIDWORKS and use local help instead, click Help > Use SOLIDWORKS Web Help.

To report problems encountered with the Web help interface and search, contact your local support representative. To provide feedback on individual help topics, use the “Feedback on this topic” link on the individual topic page.