Hide Table of Contents

Select Near and Far Side Hole Wizard Countersink Features Example (C#)

This example shows how to select near and far side Hole Wizard countersink features.

//----------------------------------------------------------------------------
// Preconditions:
// 1. Open a part that contains a Hole Wizard hole named, Hole1.
// 2. Modify the countersink diameter and angle values as required by Hole1.
// 3. Open an Immediate window.
//
// Postconditions:
// 1. Inspect the Immediate window.
// 2. The current near side countersink option is displayed.
// 3. The current far side countersink option is displayed.
// 4. The near side countersink option is toggled.
//    If the near side countersink option is selected,
//    the proper angle and diameter are set.
// 5. The far side countersink option is toggled.
//    If the far side countersink option is selected,
//    the proper angle and diameter are set.
// 6. The new near side countersink option is displayed.
// 7. The new far side countersink option is displayed.
// ---------------------------------------------------------------------------
using Microsoft.VisualBasic;
using System;
using System.Collections;
using System.Collections.Generic;
using System.Data;
using System.Diagnostics;
using SolidWorks.Interop.sldworks;
using SolidWorks.Interop.swconst;
namespace NearFarCounterSink_CSharp.csproj
{
    
partial class SolidWorksMacro
    {

        
ModelDoc2 swModel;
        
WizardHoleFeatureData2 FeatureData;
        
Feature Feature;
        
ModelDocExtension swModelDocExt;
        
SelectionMgr swSelMgr;

        
bool boolstatus;

        
public void Main()
        {
            swModel = (
ModelDoc2)swApp.ActiveDoc;
            swModelDocExt = swModel.Extension;
            swSelMgr = (
SelectionMgr)swModel.SelectionManager;

            swModel.ClearSelection2(
true);

            boolstatus = swModelDocExt.SelectByID2(
"Hole1", "BODYFEATURE", 0, 0, 0, false, 0, null, (int)swSelectOption_e.swSelectOptionDefault);
            Feature = (
Feature)swSelMgr.GetSelectedObject6(1, -1);
            FeatureData = (
WizardHoleFeatureData2)Feature.GetDefinition();

            
Debug.Print("Near side countersink option is selected: " + FeatureData.NearSideCounterSink);

            
if ((FeatureData.NearSideCounterSink))
            {
                FeatureData.NearSideCounterSink =
false;
            }
            
else
            {
                FeatureData.NearSideCounterSink =
true;
                
// near side countersink option is selected
                FeatureData.NearCounterSinkDiameter = 0.0061;
                
// meters
                FeatureData.NearCounterSinkAngle = 1.57;
                
// radians
            }

            
Debug.Print("Far side countersink option is selected: " + FeatureData.FarSideCounterSink);

            
if ((FeatureData.FarSideCounterSink))
            {
                FeatureData.FarSideCounterSink =
false;
            }
            
else
            {
                FeatureData.FarSideCounterSink =
true;
                
// far side countersink option is selected
                FeatureData.FarCounterSinkDiameter = 0.0061;
                
// meters
                FeatureData.FarCounterSinkAngle = 1.57;
                
// radians
            }

            boolstatus = Feature.ModifyDefinition(FeatureData, swModel,
null);
            FeatureData = (
WizardHoleFeatureData2)Feature.GetDefinition();

            
Debug.Print("Near side countersink option is selected: " + FeatureData.NearSideCounterSink);
            
Debug.Print("Far side countersink option is selected: " + FeatureData.FarSideCounterSink);


        }

        
public SldWorks swApp;

    }
}



Provide feedback on this topic

SOLIDWORKS welcomes your feedback concerning the presentation, accuracy, and thoroughness of the documentation. Use the form below to send your comments and suggestions about this topic directly to our documentation team. The documentation team cannot answer technical support questions. Click here for information about technical support.

* Required

 
*Email:  
Subject:   Feedback on Help Topics
Page:   Select Near and Far Side Hole Wizard Countersink Features Example (C#)
*Comment:  
*   I acknowledge I have read and I hereby accept the privacy policy under which my Personal Data will be used by Dassault Systèmes

Print Topic

Select the scope of content to print:

x

We have detected you are using a browser version older than Internet Explorer 7. For optimized display, we suggest upgrading your browser to Internet Explorer 7 or newer.

 Never show this message again
x

Web Help Content Version: API Help (English only) 2018 SP05

To disable Web help from within SOLIDWORKS and use local help instead, click Help > Use SOLIDWORKS Web Help.

To report problems encountered with the Web help interface and search, contact your local support representative. To provide feedback on individual help topics, use the “Feedback on this topic” link on the individual topic page.