İçindekiler'i Gizle

Analysis Results PropertyManager

The final step in creating a TolAnalyst study is to set and review the results. When the Results PropertyManager is activated, the results are automatically computed with the default or saved settings.

To use the Analysis Results PropertyManager:

  1. Review the results under Analysis Summary.

  2. If necessary:

  • Modify the Analysis Parameter options.

  • Under Min/Max Contributors, double-click listed dimensions and tolerances to modify their tolerance values. Click OK to close the dialog box.

  1. Click Recalculate to compute new results.

  2. If necessary, click Export Results to export the analysis results.

  3. Click .

PropertyManager Options

Analysis Parameters

Use the analysis parameters to set the evaluation criteria and precision of the results.

Orientation tolerances. Includes geometric orientation tolerances (angularity, parallelism, and perpendicularity), and angular plus and minus location tolerances in the evaluation of the worst case conditions. The results are automatically recalculated each time the option is selected or cleared.

Normal to origin feature. Updates the measurement vector to be normal to the plane or axis of the Measurement PropertyManager's Measure From feature. The results are automatically recalculated each time the option is selected or cleared.

Float fasteners and pins. Uses the clearances between the holes and fasteners to increase the worst-case minimum and maximum result. Each part can move in an amount equal to the radial distance between the hole and fastener.

Tolerance precision. Sets the precision of the results given under Analysis Summary. You can set the precision before or after the results are computed. The results are not recalculated.

Recalculate. Runs the analysis. Click Recalculate after changing the tolerance values of one or more contributing tolerances under Min/Max Contributors.

Recalculate is unavailable unless you change tolerance values of the contributing tolerances.

Analysis Summary

The analysis summary displays the results, which you can export.

Results. Lists these items:

  • The nominal value of the measurement

  • The minimum and maximum worst case conditions

  • The root sum squares (RSS) minimum and maximum worst case conditions

Export Results. Click to save the results to Excel, XML, or HTML.

Analysis Data and Display

The analysis data and display lists the contributors and manages the display in the graphics area. You can set the data and display for the minimum or maximum worst case condition.

Min/Max Contributors

The contributor list states each contributing feature and its percent contribution on the worst case minimum or maximum condition, based on the difference between the measurement nominal value and worst case result.

For example, if the nominal value is 10 mm and the worst case maximum result is 11, the feature contribution is 10% if it consumes 0.1 of the 1 mm tolerance stack.

Below each feature, the list of dimensions and tolerances that cause the contribution are displayed. When you select an item in the list, the dimension or tolerance appears in the graphics area. Double-click an item in the list to open the Dimension Tolerance or Change Geometric Tolerance dialog box where you can modify the tolerance values. With these two dialogs, you are editing the part. These are not temporary overrides to values. After modifying tolerance values, click Recalculate to compute new results.

Graphics Area Display

The graphics area display for the minimum and maximum worst case result includes:

 

 

  • A callout stating the result, attached at the point in which the result occurs

Red for Min and blue for Max

 

 

  • An outline of the resulting actual feature displayed in yellow

 

 

  • Arrowheads directed from the nominal feature to the actual feature. Under Analysis Data and Display, select MAX or MIN to toggle between displays.

 

 

  • Hover over an arrowhead to display a tooltip that shows the corresponding displacement (D), vector (V), and point (P) coordinate.

Warnings

When TolAnalyst evaluates the study, warning messages appear if there are potential problems with the setup and evaluation. When TolAnalyst identifies the following condition, consider the results with caution.

Incomplete Tolerance Chains

This warning appears when a complete tolerance chain does not exist between the two measurement features.

When performing a study on the distance between the two holes in this assembly, a warning appears about an incomplete tolerance chain.

 

 

The warning appears because in the parts, there are no dimensions or tolerances controlling the location of the hole, which is under constrained.



Bu başlık hakkında geribildirimde bulunun

SOLIDWORKS; dokümantasyonun sunumu, doğruluğu ve bütünlüğü hakkında geribildiriminizi almaktan memnuniyet duyar. Bu başlık ile ilgili yorum ve önerilerinizi, aşağıdaki formu kullanarak doğrudan dokümantasyon takımımıza yollayın. Dokümantasyon takımı teknik destek sorularına yanıt veremez. Teknik destek ile ilgili bilgiler için buraya tıklayın.

* Gerekli

 
*Email:  
Konu:   Yardım Başlıkları Hakkında Geribildirim
Sayfa:   Analysis Results PropertyManager
*Yorum:  
*   Kişisel Bilgilerimin Dassault Systèmes tarafından kullanılacağının belirtildiği gizlilik politikasını okuduğumu ve kabul ettiğimi onaylıyorum

Yazdırma Başlığı

Yazdırılacak içeriğin kapsamını seçin:

x

Internet Explorer 7'den daha eski bir tarayıcı sürümünü kullandığınızı tespit ettik. Optimize edilmiş görünüm için tarayıcınızı Internet Explorer 7 veya daha yenisine yükseltmenizi öneririz.

 Bu mesajı bir daha asla gösterme
x

Web Yardım İçerik Sürümü: SOLIDWORKS 2011 SP05

SOLIDWORKS içindeki Web yardımını devre dışı bırakmak ve onun yerine yerel yardımı kullanmak için Yardım > SOLIDWORKS Web Yardımını Kullan öğelerine tıklayın.

Web yardımı arabirimi ve araması ile ilgili karşılaştığınız sorunları lütfen yerel destek temsilcinize bildirin. Yardım başlıkları hakkında ayrı ayrı geri bildirimde bulunmak için ilgili başlığın sayfasından "Bu başlık hakkında geribildirim" bağlantısına tıklayın.