Thermal Contact Resistance

The usefulness of the analogy between the flow of electric current and the flow of heat becomes apparent when a satisfactory description of the heat transfer at the interface of two conducting media is needed. Due to machining limitations, no two solid surfaces will ever form a perfect contact when they are pressed together. Tiny air gaps will always exist between the two contacting surfaces due to their roughness.

Through the interface between the two contacting faces, two modes of heat transfer exist. The first is conduction through points of solid-to-solid contact (Qconduction) which is very effective. Secondly, conduction through the gas filled gaps (Qgap) which, due to its low thermal conductivity, can be very poor. To treat the thermal contact resistance, an interfacial conductance, hc, is placed in series with the conducting media on both sides as shown in the next figure.

The conductance hc is similar to the convection heat transfer coefficient and has the same units (W/m2 oK). If DT is the temperature difference across an interface of area A, then the rate of heat transfer Q is given by Q = A hc DT. Using the electrical-thermal analogy, you can write Q = DT/Rt, where Rt is the thermal contact resistance and is given by Rt = 1/(A hc).

The interfacial conductance, hc, depends on the following factors:

  • The surface finish of the contacting faces.

  • The material of each face.

  • The pressure with which the surfaces are forced together.

  • The substance in the gaps between the two contacting faces.

The following table shows some typical values of the interfacial conductance for normal surface finishes and moderate contact pressures (1 to 10 atm). Air gaps not evacuated unless so indicated:

Contacting Faces

Conductance (hc) (W/m2 oK)

Iron/aluminum

45,000

Copper/copper

10,000 - 25,000

Aluminum/aluminum

2200 - 12000

Stainless steel/stainless steel

2000 - 3700

Stainless steel/stainless steel

(evacuated gaps)

200 - 1100

Ceramic/ceramic

500 - 3000

The following table lists the thermal contact resistance for metallic interfaces under vacuum conditions:

Thermal Resistance, RthermalX10-4 (m2.K/W)

Contact Pressure

100 kN/m2

10,000 kN/m2

Stainless Steel

6-25

0.7-4.0

Copper

1-10

0.1-0.5

Magnesium

1.5-3.5

0.2-0.4

Aluminum

1.5-5.0

0.2-0.4

An Example of Thermal Contact Resistance Modeling

 



Bu başlık hakkında geribildirimde bulunun

SOLIDWORKS; dokümantasyonun sunumu, doğruluğu ve bütünlüğü hakkında geribildiriminizi almaktan memnuniyet duyar. Bu başlık ile ilgili yorum ve önerilerinizi, aşağıdaki formu kullanarak doğrudan dokümantasyon takımımıza yollayın. Dokümantasyon takımı teknik destek sorularına yanıt veremez. Teknik destek ile ilgili bilgiler için buraya tıklayın.

* Gerekli

 
*Email:  
Konu:   Yardım Başlıkları Hakkında Geribildirim
Sayfa:   Thermal Contact Resistance
*Yorum:  
*   Kişisel Bilgilerimin Dassault Systèmes tarafından kullanılacağının belirtildiği gizlilik politikasını okuduğumu ve kabul ettiğimi onaylıyorum

Yazdırma Başlığı

Yazdırılacak içeriğin kapsamını seçin:




x

Internet Explorer 7'den daha eski bir tarayıcı sürümünü kullandığınızı tespit ettik. Optimize edilmiş görünüm için tarayıcınızı Internet Explorer 7 veya daha yenisine yükseltmenizi öneririz.

 Bu mesajı bir daha asla gösterme
x

Web Yardım İçerik Sürümü: SOLIDWORKS 2011 SP05

SOLIDWORKS içindeki Web yardımını devre dışı bırakmak ve onun yerine yerel yardımı kullanmak için Yardım > SOLIDWORKS Web Yardımını Kullan öğelerine tıklayın.

Web yardımı arabirimi ve araması ile ilgili karşılaştığınız sorunları lütfen yerel destek temsilcinize bildirin. Yardım başlıkları hakkında ayrı ayrı geri bildirimde bulunmak için ilgili başlığın sayfasından "Bu başlık hakkında geribildirim" bağlantısına tıklayın.