Inserting P and ID Equipment
After importing P and ID data to the Piping and Instrumentation tab of the Task Pane, you can insert all equipment to the routing assembly.
-
On the Piping and Instrumentation tab, for Sort by, select Equipment.
You can enter the first few characters of equipment names in
Search Equipment to filter the list.
Equipment that is not yet inserted is indicated with a red flag
.
- Click Insert All Equipment.
The Insert Component dialog box appears.
-
Drag the equipment components from the dialog box to the graphics area to place them in the assembly.
If there is not enough information in the P&ID file to identify a selected component, the
Select Component dialog box appears. In that case:
-
Select a component and configuration from the list.
- Click Open and place the item in the graphics area.
- When you have placed all components, click
.Correctly placed components are indicated with a green flag
.