This example shows how to set a fully resolved assembly to lightweight.
'------------------------------------------
'
' Preconditions:
' (1)
Assembly is open.
' (2)
Assembly is fully resolved.
'
' Postconditions: Assembly is lightweight.
'
'------------------------------------------
Option Explicit
Public Enum swDocumentTypes_e
swDocNONE
= 0
swDocPART
= 1
swDocASSEMBLY
= 2
swDocDRAWING
= 3
End Enum
Public Enum swComponentResolveStatus_e
swResolveOk
= 0
swResolveAbortedByUser
= 1
swResolveNotPerformed
= 2
swResolveError
= 3
End Enum
Public Enum swComponentSuppressionState_e
swComponentSuppressed
= 0
swComponentLightweight
= 1
swComponentFullyResolved
= 2
End Enum
Public Enum swSuppressionError_e
swSuppressionBadComponent
= 0
swSuppressionBadState
= 1
swSuppressionChangeOk
= 2
swSuppressionChangeFailed
= 3
End Enum
Sub SetComponentLightWeight _
( _
sPadStr
As String, _
swComp
As SldWorks.Component _
)
Dim
vChildArr As
Variant
Dim
swChildComp As
SldWorks.Component2
Dim
swChildModel As
SldWorks.ModelDoc2
Dim
nRetVal As
Long
Dim
nDocType As
Long
Dim
i As
Long
Debug.Print
sPadStr & swComp.Name2 &
" [" & CBool(swComp.Visible)
& "]"
vChildArr
= swComp.GetChildren
For
i = 0 To UBound(vChildArr)
Set
swChildComp = vChildArr(i)
'
Is NULL if another instance has been previously set to lightweight
Set
swChildModel = swChildComp.GetModelDoc
If
Not swChildModel Is Nothing Then
nDocType
= swChildModel.GetType
Else
nDocType
= swDocNONE
End
If
nRetVal
= swChildComp.SetSuppression2(swComponentLightweight)
If
swDocPART = nDocType Or swDocNONE = nDocType Then
Debug.Assert
swResolveNotPerformed = nRetVal
Else
'
Cannot set a sub-assembly to lightweight; must set each part to lightweight
Debug.Assert
swDocASSEMBLY = swChildModel.GetType
Debug.Assert
swResolveError = nRetVal
End
If
'
Recurse into this component
SetComponentLightWeight
sPadStr & " ",
swChildComp
Next
i
End Sub
Sub main()
Dim
swApp As
SldWorks.SldWorks
Dim
swModel As
SldWorks.ModelDoc2
Dim
swAssy As
SldWorks.AssemblyDoc
Dim
swConfig As
SldWorks.Configuration
Dim
swConfigMgr As
SldWorks.ConfigurationManager
Dim
swRootComp As
SldWorks.Component2
Dim
bRet As
Boolean
Set
swApp = Application.SldWorks
Set
swModel = swApp.ActiveDoc
Set
swAssy = swModel
Set
swConfigMgr = swModel.ConfigurationManager
Set
swConfig = swConfigMgr.ActiveConfiguration
Set
swRootComp = swConfig.GetRootComponent
Debug.Print
"File = " & swModel.GetPathName
SetComponentLightWeight
" ",
swRootComp
'
Update in-context features
bRet
= swModel.ForceRebuild3(False):
Debug.Assert bRet
End Sub