Expand GirişGiriş
Expand YönetimYönetim
Expand Kullanıcı ArayüzüKullanıcı Arayüzü
Expand SolidWorks TemelleriSolidWorks Temelleri
Expand 2B'den 3B'ye geçiş2B'den 3B'ye geçiş
Expand MontajlarMontajlar
Expand CircuitWorksCircuitWorks
Expand KonfigürasyonlarKonfigürasyonlar
Expand SolidWorks CostingSolidWorks Costing
Expand Design CheckerDesign Checker
Expand SolidWorks'te Tasarım EtütleriSolidWorks'te Tasarım Etütleri
Expand Detaylandırma ve Teknik ResimlerDetaylandırma ve Teknik Resimler
Expand DFMXpressDFMXpress
Expand DriveWorksXpressDriveWorksXpress
Expand FloXpressFloXpress
Expand Al ve VerAl ve Ver
Expand Model GörünümüModel Görünümü
Expand Kalıp TasarımıKalıp Tasarımı
Expand Hareket EtütleriHareket Etütleri
Expand Parçalar ve UnsurlarParçalar ve Unsurlar
Expand TesisatTesisat
Expand Sac LevhaSac Levha
Collapse SimülasyonSimülasyon
Expand SimulationXpressSimulationXpress
Expand ÇizmeÇizme
Expand Sustainability ÜrünleriSustainability Ürünleri
Expand SolidWorks UtilitiesSolidWorks Utilities
Expand ToleranslamakToleranslamak
Expand TolAnalystTolAnalyst
Expand ToolboxToolbox
Expand Kaynaklı MontajlarKaynaklı Montajlar
Expand Workgroup PDMWorkgroup PDM
Expand Sorun GidermeSorun Giderme
Terimler
İçindekiler'i Gizle

Add Event (Variable) PropertyManager

The Add Event (Variable) PropertyManager allows you to define a variable amplitude event for a fatigue study. You can define multiple fatigue events for one fatigue study. A variable amplitude fatigue event refers to one or more static studies, or to a particular solution step of a nonlinear or time history linear dynamic study.

Load

  Get Curve Opens the Load History Curve dialog to define the curve data. You can define the curve manually or load a predefined history.
The Simulation Curve library includes sample Load History curves from SAE.
  View Graphs the load history curve.
Study Association Sets the reference static study.

No.

Study counter. Only one study is allowed for each variable amplitude event.

Study.

Click in this cell to select a study from the drop-down menu. The list of studies includes the studies that are associated with the currently active configuration only.

The program uses linear theory. Scaling results is invalid if the static study includes nonlinear effects such as contact or large displacements.

Scale.

Use this scale factor to relate the amplitudes of the variable load history curve to the load in the study. You cannot scale loads defined in a nonlinear study.

For example if the amplitudes are measured in volts, the scale factor must relate Volts to the load in the study.

Example: Suppose that you applied a force of 500 Newtons to a face in the reference static study, and the load history curve measures the force on the same face where a force of 800 Newtons is measured as 1.2 Volts. The scale factor that you should use in this case is (800/1.2)/500=1.92.

The load history can represent strain values.

Example: Suppose that the load history curve measures strain in a certain direction at a certain location. The scale in this case should be (1/s) where s is the strain in the same direction and at the same location in the reference static study.
When finding s from the study, you may need to average the strain at several elements.

If the model is subjected to multiple loads, define multiple studies with one load in each study. You can then define one event for each load case with the proper scale factor.

Option

  Number of Repeats.

Repeats the curve data the specified number of times.

Example:
No. of Repeats = 1 No. of Repeats = 3
  Event Start Time.

Use this entry to time the selected multiple events. This input is ignored if you define a single event for the study.

Example:
Event start time = 0 Event start time = 50


Bu başlık hakkında geribildirimde bulunun

SOLIDWORKS; dokümantasyonun sunumu, doğruluğu ve bütünlüğü hakkında geribildiriminizi almaktan memnuniyet duyar. Bu başlık ile ilgili yorum ve önerilerinizi, aşağıdaki formu kullanarak doğrudan dokümantasyon takımımıza yollayın. Dokümantasyon takımı teknik destek sorularına yanıt veremez. Teknik destek ile ilgili bilgiler için buraya tıklayın.

* Gerekli

 
*Email:  
Konu:   Yardım Başlıkları Hakkında Geribildirim
Sayfa:   Add Event (Variable) PropertyManager
*Yorum:  
*   Kişisel Bilgilerimin Dassault Systèmes tarafından kullanılacağının belirtildiği gizlilik politikasını okuduğumu ve kabul ettiğimi onaylıyorum

Yazdırma Başlığı

Yazdırılacak içeriğin kapsamını seçin:

x

Internet Explorer 7'den daha eski bir tarayıcı sürümünü kullandığınızı tespit ettik. Optimize edilmiş görünüm için tarayıcınızı Internet Explorer 7 veya daha yenisine yükseltmenizi öneririz.

 Bu mesajı bir daha asla gösterme
x

Web Yardım İçerik Sürümü: SOLIDWORKS 2013 SP05

SOLIDWORKS içindeki Web yardımını devre dışı bırakmak ve onun yerine yerel yardımı kullanmak için Yardım > SOLIDWORKS Web Yardımını Kullan öğelerine tıklayın.

Web yardımı arabirimi ve araması ile ilgili karşılaştığınız sorunları lütfen yerel destek temsilcinize bildirin. Yardım başlıkları hakkında ayrı ayrı geri bildirimde bulunmak için ilgili başlığın sayfasından "Bu başlık hakkında geribildirim" bağlantısına tıklayın.