Expand GirişGiriş
Expand YönetimYönetim
Expand Kullanıcı ArayüzüKullanıcı Arayüzü
Expand SolidWorks TemelleriSolidWorks Temelleri
Expand 2B'den 3B'ye geçiş2B'den 3B'ye geçiş
Expand MontajlarMontajlar
Expand CircuitWorksCircuitWorks
Expand KonfigürasyonlarKonfigürasyonlar
Expand SolidWorks CostingSolidWorks Costing
Expand Design CheckerDesign Checker
Expand SolidWorks'te Tasarım EtütleriSolidWorks'te Tasarım Etütleri
Expand Detaylandırma ve Teknik ResimlerDetaylandırma ve Teknik Resimler
Expand DFMXpressDFMXpress
Expand DriveWorksXpressDriveWorksXpress
Expand FloXpressFloXpress
Expand Al ve VerAl ve Ver
Expand Model GörünümüModel Görünümü
Expand Kalıp TasarımıKalıp Tasarımı
Expand Hareket EtütleriHareket Etütleri
Expand Parçalar ve UnsurlarParçalar ve Unsurlar
Expand TesisatTesisat
Expand Sac LevhaSac Levha
Collapse SimülasyonSimülasyon
Expand SimulationXpressSimulationXpress
Expand ÇizmeÇizme
Expand Sustainability ÜrünleriSustainability Ürünleri
Expand SolidWorks UtilitiesSolidWorks Utilities
Expand ToleranslamakToleranslamak
Expand TolAnalystTolAnalyst
Expand ToolboxToolbox
Expand Kaynaklı MontajlarKaynaklı Montajlar
Expand Workgroup PDMWorkgroup PDM
Expand Sorun GidermeSorun Giderme
Terimler
İçindekiler'i Gizle

Thermal - Options

The Thermal dialog box lets you select the desired options for a thermal study.

To access the Thermal options dialog box, right-click the icon of a thermal study in the Simulation study tree and select Properties.

Solution Type

Transient Check this button to run transient thermal analysis.
Total time Specifies the total time of interest (T) for a transient analysis. Default is 1.0 sec.
Time increment Specifies the increment of time (Δt) for transient solution steps. Default is 0.1 sec. The program calculates the solution at Δt, 2(Δt), 3(Δt), 4(Δt),..., and T, where Δt is the time increment and T is the specified total time.
Initial temperatures from thermal study Uses the temperatures calculated from a thermal study (steady state or transient) as an initial condition for the transient thermal study. Select the desired Thermal study and specify the Time steps at which you want to use the temperature profile as an initial condition (for steady state thermal studies, the Time steps field is set to 1).
Steady State Check this option to specify steady state thermal analysis.

Fluid convection option

Include fluid convection effects from SolidWorks Flow Simulation Check this option to read the convection coefficient calculated from a completed Flow Simulation study on the same configuration from a file. Select the desired Flow Simulation Result Files (*.fld) that has been generated by Flow Simulation . The model name, configuration name, and flow iteration number associated with the specified file are displayed. This option is not available for 2D simplification studies.
To view a plot of the imported convection on the model, right-click the convection icon in the Simulation study tree and select Show Plot. The model must be meshed before the plot option is available.

Solver

Lets you specify the solver to be used when running the study.

Automatic Check this option to allow the software to choose the solver to be used.
Direct sparse Check this option to use the Direct Sparse solver when running the study.
FFEPlus Check this option to use the FFEPlus solver when running the study.
Results folder Accept the default folder or browse to select another location for the results.
Advanced Options Switches to the Advanced tab of this dialog box.

Recommended Time Increment for Thermal Studies

The recommended time step size Δt for a transient thermal analysis is related to element conduction length and material properties.

The larger the thermal diffusivity, the smaller the Δt and element length should be. The recommended time step is given as:

Δt ≤ δ2 ∕ 4α

α = thermal diffusivity = K / ρc (Units are length2 / time)

δ = conducting length (for line elements this is the element's length, for plane or volume elements, it is the diagonal of the inscribed circle or sphere)

K = conductivity

ρ = mass density

c = specific heat



Bu başlık hakkında geribildirimde bulunun

SOLIDWORKS; dokümantasyonun sunumu, doğruluğu ve bütünlüğü hakkında geribildiriminizi almaktan memnuniyet duyar. Bu başlık ile ilgili yorum ve önerilerinizi, aşağıdaki formu kullanarak doğrudan dokümantasyon takımımıza yollayın. Dokümantasyon takımı teknik destek sorularına yanıt veremez. Teknik destek ile ilgili bilgiler için buraya tıklayın.

* Gerekli

 
*Email:  
Konu:   Yardım Başlıkları Hakkında Geribildirim
Sayfa:   Thermal - Options
*Yorum:  
*   Kişisel Bilgilerimin Dassault Systèmes tarafından kullanılacağının belirtildiği gizlilik politikasını okuduğumu ve kabul ettiğimi onaylıyorum

Yazdırma Başlığı

Yazdırılacak içeriğin kapsamını seçin:

x

Internet Explorer 7'den daha eski bir tarayıcı sürümünü kullandığınızı tespit ettik. Optimize edilmiş görünüm için tarayıcınızı Internet Explorer 7 veya daha yenisine yükseltmenizi öneririz.

 Bu mesajı bir daha asla gösterme
x

Web Yardım İçerik Sürümü: SOLIDWORKS 2013 SP05

SOLIDWORKS içindeki Web yardımını devre dışı bırakmak ve onun yerine yerel yardımı kullanmak için Yardım > SOLIDWORKS Web Yardımını Kullan öğelerine tıklayın.

Web yardımı arabirimi ve araması ile ilgili karşılaştığınız sorunları lütfen yerel destek temsilcinize bildirin. Yardım başlıkları hakkında ayrı ayrı geri bildirimde bulunmak için ilgili başlığın sayfasından "Bu başlık hakkında geribildirim" bağlantısına tıklayın.