No.
|
Study counter. You can specify more than one study only if you select Find cycle peaks.
|
Study.
|
Sets the reference study. Click in this cell to select a study from the drop-down menu. For a references study, you can select a static study, or stress results from a particular solution step of a nonlinear or linear dynamic study.
The list of studies includes the studies that are associated with the currently active configuration only.
|
Scale.
|
This scale factor lets you define a fatigue event based on a reference study with scaled loads. Since the study is linear, the program uses this factor to scale the stresses. You cannot scale loads defined in a nonlinear study.
For example, if the reference study has a pressure load of 50 psi applied to a face and you want to define a fatigue load based on 150 psi on the same face, you should enter a scale factor of 150/50 = 3. The program multiplies the stress results of the reference study by this factor to calculate stress values for use in calculating alternating stresses.
If you select Find cycle peaks, you can continue to define more rows. Double-click in the No. cell to add a row. All studies must have the same mesh.
|
Step.
|
Sets the solution step for the reference nonlinear or linear dynamic study. The program uses the stress results of this particular step to calculate the alternating stresses.
|