Expand SolidWorks Enterprise PDM 파일 탐색기SolidWorks Enterprise PDM 파일 탐색기
Expand SolidWorks Enterprise PDM 항목 탐색기SolidWorks Enterprise PDM 항목 탐색기
Collapse SolidWorks Enterprise PDM 관리도구SolidWorks Enterprise PDM 관리도구
Expand Introducing the Administration ToolIntroducing the Administration Tool
Expand Local SettingsLocal Settings
Expand VaultsVaults
Expand Archive ServersArchive Servers
Expand Enterprise PDM Add-insEnterprise PDM Add-ins
Expand DispatchDispatch
Expand Bills of MaterialsBills of Materials
Expand Data CardsData Cards
Expand Card ListsCard Lists
Expand CategoriesCategories
Expand ColumnsColumns
Expand File TypesFile Types
Expand Importing and Exporting DataImporting and Exporting Data
Expand Indexing the VaultIndexing the Vault
Expand ItemsItems
Expand  Installing and Configuring SolidNetWork Licensing Installing and Configuring SolidNetWork Licensing
Expand Message SystemMessage System
Expand Revision NumbersRevision Numbers
Expand Serial NumbersSerial Numbers
Expand  Tasks Tasks
Expand TemplatesTemplates
Expand ToolboxToolbox
Collapse Users and GroupsUsers and Groups
Expand VariablesVariables
Expand WorkflowsWorkflows
Expand Administering Web ServersAdministering Web Servers
Expand Database ServerDatabase Server
Expand MiscellaneousMiscellaneous
Expand SolidWorks Enterprise PDM 보관 서버 구성 도구SolidWorks Enterprise PDM 보관 서버 구성 도구
Expand SolidWorks Enterprise PDM 파일 버전 업그레이드 도구SolidWorks Enterprise PDM 파일 버전 업그레이드 도구
목차 숨기기

Settings Dialog Box - Reference Dialog

Use the Reference Dialog page to control how the Enterprise PDM software handles references when users check out or change the state of parent files.

To display the Settings dialog box:

  1. Right-click a user or group and select Settings.
  2. In the left pane of the user's Settings dialog box, click Reference Dialog.

Check out and version access controls

Auto select reference files to get latest when checking out. When selected, in the Check Out dialog box, the software pre-selects the Get check box if the latest version of a referenced file is not in the local cache.

If the user does not clear the selections in the Get column of the Check Out dialog box, when the user checks out the parent file, the software copies the latest version of the referenced files to the user's local cache.

This option is enabled by default.

When cleared, the software pre-selects the Get check box for referenced files that are not cached locally. However, it does not select the Get check box if an older version of the referenced file is cached.

If you clear this option and select any of the following options, the software enables it again.
  Always work with the latest version of files. Copies the latest version of a file to the user's local cache when the user views or opens the file.

If the file the user is opening contains references, the software retrieves the latest version of all referenced files to the user's local cache, regardless of which version of the references are attached or if older versions are stored in the local cache.

When you select this option, the user only sees the Get Latest Version command in the short-cut menu for files and folders in Windows Explorer.

To allow the user to retrieve older versions of files from the SOLIDWORKS Add-in, select this option and then select Enable the Get Version command in SOLIDWORKS Add-in.

This option was previously available on the Explorer tab of the Settings dialog box, under Miscellaneous.
  Check out files silently without showing the check out dialog box

Prevents the display of the Check Out dialog box when the user checks out files with references. The software only checks out the selected files; the user must check out each referenced file separately.

  Try to check out all referenced files when the referencing file is checked out.

When the user checks out a file with references to other files, the referenced files are also marked for check out (if it is possible).

If you select the option to check out files silently as well, checking out a parent file automatically checks out all referenced files.

Miscellaneous

Do not mark referenced files when changing state. If selected, when a user changes the state of the parent file, referenced files are NOT marked (the checkboxes in the Change State column are not checked) and the referenced files are not included in the state change.

If cleared (the default), when changing state on a file, all referenced children are also marked in the Change State dialog box.

Show "not rebuilt" warning on drawing and assemblies in need of rebuilding.

Displays a warning during check in if a part has been updated more recently than a drawing or assembly that references it

A help button in the warning displays instructions for rebuilding the affected files.

This option is enabled by default.



이 도움말에 대한 피드백 제공

SOLIDWORKS는 도움말 정보의 개선을 위한 고객님의 제안 사항과 의견을 환영합니다. 제안하고자 하는 의견을 아래 양식에 작성하여 도움말 문서 팀에 직접 전달할 수 있습니다. 문서 팀은 제품에 관한 기술적인 지원은 하지 않습니다. 기술 지원에 관한 정보는 여기를 클릭하십시오.

* 필수 입력

 
*전자 메일:  
제목:   도움말에 대한 피드백
페이지:   Settings Dialog Box - Reference Dialog
*사용자 의견:  
*   개인정보 보호정책을 읽었으며 본 정책에 따라 Dassault Systèmes에서 내 개인 정보를 사용하는 것에

인쇄 항목

인쇄할 콘텐츠 범위 선택:

x

Internet Explorer 7 이전 버전을 사용하고 있습니다. 페이지를 최적화하려면 사용 브라우저를 Internet Explorer 7 이상으로 업그레이드합니다.

 이 메시지를 다시 표시하지 않음
x

웹 도움말 콘텐츠 버전: SOLIDWORKS PDM 2014 SP05

SOLIDWORKS에서 웹 도움말 기능을 비활성화하고 로컬 도움말을 사용하려면, 도움말 > SOLIDWORKS 웹 도움말 사용을 클릭합니다.

웹 도움말 인터페이스나 검색 기능에서 발생한 오류 사항을 보고하려면, 로컬 지원 서비스 담당자에게 문의하십시오. 개별 도움말 항목에 대한 피드백을 제공하려면, 각 도움말 페이지의 "이 단원에 대한 피드백 제공" 링크를 사용하십시오.