This example shows how to create a SpeedPak configuration for the active configuration.
'----------------------------------------------------------------------------
' Preconditions: Open an assembly.
'
' Postconditions:
' 1. Adds active_configuration (Default_speedpak) to the
' ConfigurationManager.
' 2. Click the ConfigurationManager tab and expand Default.
'---------------------------------------------------------------------------
Option Explicit
Sub main()
Dim SwApp As SldWorks.SldWorks
Dim Part As SldWorks.ModelDoc2
Dim boolstatus As Boolean
Dim ConfigMgr As SldWorks.ConfigurationManager
Set SwApp = Application.SldWorks
If SwApp Is Nothing Then Exit Sub
Set Part = SwApp.ActiveDoc
Set ConfigMgr = Part.ConfigurationManager
' Add a SpeedPak configuration with a part/body
selection threshold of 0.5 to the active configuration
ConfigMgr.AddSpeedPak2 1, 0.5
boolstatus = Part.ForceRebuild3(False)