You add hole callouts to annotate the Toolbox holes in your drawing with dimensions and descriptions.
You can create a hole table by selecting holes with callouts. The table lists the locations and descriptions of the selected holes.
The format and content of hole callouts depends on:
- Hole category
Counterbore
Countersink
Thru Hole
Tap
Slot callouts are not available.
- Whether the end condition is Blind or Thru in the hole's properties.
- Settings you specify in the Toolbox - Hole Callouts dialog box.
You can select to:
- Display the callout using Symbols and text or just text (Traditional)
- Preface the callout with the number of holes that exactly match the hole you apply the callout to.
- Append a description to a traditional callout.
The following tables show the callout values:
Counterbore Hole Callouts
Symbol
End condition Blind

End condition Thru

Traditional
End condition - Blind

End condition - Thru

Condition |
Output |
If the end condition is Blind
If the end condition is Thru
|
hole diameter DRILL hole depth DEEP
hole diameter DRILL THRU
|
Always displayed. |
c'bore diameter C'BORE c'bore depth and head clearance DEEP |
If Near side c'sink diameter and angle > 0° |
near-side c'sink angle° CSINK TO near-side c'sink diameter NEAR SIDE |
If Under head c'sink diameter and angle > 0° |
under head c'sink angle° CSINK TO under head c'sink diameter MID SIDE |
If Far side c'sink diameter and angle > 0° (Not applicable for Blind end condition)
|
far side c'sink angle° CSINK TO far side c'sink diameter FAR SIDE |
Countersink Hole Callouts
Symbol
Condition |
Output |
If the end condition is Blind
If the end condition is Thru
|
hole diameter hole depth
hole diameter THRU
|
Always displayed. |
c'sink diameter X c'sink angle° |
If Far side c'sink diameter and angle > 0° (Not applicable for Blind end condition)
|
far side c'sink diameter X far side c'sink angle° FAR SIDE |
Traditional
Condition |
Output |
If the end condition is Blind
If the end condition is Thru
|
hole diameter DRILL hole depth DEEP
hole diameter DRILL THRU
|
Always displayed. |
c'sink diameter CSINK TO c'sink angle° |
If Far side c'sink diameter and angle > 0° (Not applicable for Blind end condition)
|
far side c'sink angle° CSINK TO far side c'sink diameter FAR SIDE |
Thru Hole Callouts
Symbols
Condition |
Output |
If the end condition is Blind
If the end condition is Thru
|
hole diameter hole depth
hole diameter THRU
|
If Near side c'sink diameter and angle > 0° |
near-side c'sink diameter X near-side c'sink angle° NEAR SIDE |
If Far side c'sink diameter and angle > 0° (Not applicable for Blind end condition)
|
far side c'sink diameter X far side c'sink angle° FAR SIDE |
Traditional
Condition |
Output |
If the end condition is Blind
If the end condition is Thru
|
hole diameter DRILL hole depth DEEP
hole diameter DRILL THRU
|
If Near side c'sink diameter and angle > 0° |
near-side c'sink angle° CSINK TO near-side c'sink diameter NEAR SIDE |
If Far side c'sink diameter and angle > 0° (Not applicable for Blind end condition)
|
far side c'sink angle° CSINK TO far side c'sink diameter FAR SIDE |
Tap Hole Callouts
Symbols
Traditional
Condition |
Output |
If the end condition is Blind
If the end condition is Thru
|
tap drill diameter DRILL tap drill depth DEEP
tap drill diameter THRU
|
Always displayed. |
tap thread size, C'BORE tap thread depth DEEP |
If Near side c'sink diameter and angle > 0° |
near-side c'sink angle° CSINK TO near-side c'sink diameter NEAR SIDE |
If Far side c'sink diameter and angle > 0° (Not applicable for Blind end condition)
|
far side c'sink angle° CSINK TO far side c'sink diameter FAR SIDE |