This example shows how to get the forces, bending moments, and torques for a selected connector at a specified time.

'---------------------------------------------------------------------------
' Preconditions:
' 1. Add the SOLIDWORKS Simulation as an add-in (in SOLIDWORKS, click 
'    Tools > Add-ins > SOLIDWORKS Simulation > OK).

' 2. Add the SOLIDWORKS Simulation primary interop assembly as a reference
'    (in the IDE, click Project > Add Reference > .NET > 
'    SolidWorks.Interop.cosworks > OK).

' 3. Ensure the specified model exists.
' 4. Open the Immediate window.
'
' Postconditions: Inspect the Immediate window for the connector forces,
' moments, and torques.
'
' NOTE: Because the model is used elsewhere, do not save changes.
'-------------------------------------------------------------------------
Imports SolidWorks.Interop.sldworks
Imports SolidWorks.Interop.swconst
Imports SolidWorks.Interop.cosworks
Imports System.Runtime.InteropServices
Imports System
Imports System.Diagnostics

Partial Class SolidWorksMacro

    
Function VerifyLong(ByVal SwApp As SldWorks, ByVal lExpected As Long, ByVal lActual As Long, ByVal sMessage As String) As Boolean
        'This function will compare two long values for equivalence.
        'If they are different, an error message is reported with {sMessage}
        'as title, and the function returns false.
        'If equivalent, the function returns true.
        VerifyLong = True
        If lActual <> lExpected Then
            ErrorMsg(SwApp, sMessage & ": Expected = " & CStr(lExpected) & " , Actual = " & CStr(lActual))
            VerifyLong =
False
        End If
    End Function

    Function VerifyTolerance(ByVal SwApp As SldWorks, ByVal dExpected As Double, ByVal dActual As Double, ByVal dTol As Double, ByVal sMessage As String) As Boolean
        'This function will compare two double values to ensure that the actual
        'value is within the specified tolerance range
        'of the expected value. If the actual is not within the tolerance range,
        'an error message is reported with {sMessage}
        'as title, and the function returns false.  
        'Otherwise, the function returns true to indicate equivalence/success.

        VerifyTolerance = True
        If (dActual < ((1 - dTol) * dExpected)) Or (dActual > ((1 + dTol) * dExpected)) Then
            ErrorMsg(SwApp, sMessage & ": Expected = " & CStr(dExpected) & " , Actual = " & CStr(dActual) & " , Tolerance = " & CStr(dTol) & " percent")
            VerifyTolerance =
False
        End If
    End Function

    Sub ErrorMsg(ByVal SwApp As SldWorks, ByVal Message As String)
        SwApp.SendMsgToUser2(Message, 0, 0)
        SwApp.RecordLine(
"'*** WARNING - General")
        SwApp.RecordLine(
"'*** " & Message)
        SwApp.RecordLine(
"")
    
End Sub

    Sub main()

        
Dim Part As ModelDoc2

        
Dim COSMOSWORKS As CosmosWorks, CWAddinCallBack As CwAddincallback, ActDoc As CWModelDoc
        
Dim StudyMngr As CWStudyManager, Study As CWStudy, CWMesh As CWMesh
        
Dim StudyOptions As Object, CWFeatObj As CWResults, ActDocExt As ModelDocExtension

        
Dim sModelName As String, sStudyName As String
        Dim sStudyConfig As String

        Dim longstatus As Long, longwarnings As Long, errCode As Integer
        Dim accurateTime as Double

        Dim el As Double, el_hold As Double
        Dim tl As Double, tl_hold As Double

        Dim UResMax As Double, Tol1 As Double

        Dim bStudyFound As Boolean

        Dim Force(15) As Object

        Dim iMeshUnit As Integer, iSolverType As Integer, iNumberOfStudies As Integer
        Dim ix As Integer, iStudyType As Integer

        'Model names
        sModelName = "C:\Users\Public\Documents\SOLIDWORKS\SOLIDWORKS 2018\samples\tutorial\api\beam_boltconnection.sldasm"

        'SOLIDWORKS configuration for which study is active (Blank "" = use default)
        sStudyConfig = ""
        'Study name                      
        sStudyName = "Study 1"

        iSolverType = swsSolverType_e.swsSolverTypeDirectSparse 'Solver type

        Part = swApp.OpenDoc6(sModelName, swDocumentTypes_e.swDocASSEMBLY, 1, "", longstatus, longwarnings)
        
If Part Is Nothing Then ErrorMsg(SwApp, "Failed to open: " & sModelName)

        CWAddinCallBack = SwApp.GetAddInObject(
"SldWorks.Simulation")
        
If CWAddinCallBack Is Nothing Then ErrorMsg(SwApp, "No CWAddinCallBack object")
        COSMOSWORKS = CWAddinCallBack.COSMOSWORKS
        
If COSMOSWORKS Is Nothing Then ErrorMsg(SwApp, "No CosmosWorks object")

        
'Get active document
        ActDoc = COSMOSWORKS.ActiveDoc
        
If ActDoc Is Nothing Then ErrorMsg(SwApp, "Failed to get active document")

        
'If needed, rebuild the model
        ActDocExt = Part.Extension
        
If (ActDocExt.NeedsRebuild = True) Then
            Part.ForceRebuild3(False)
        
End If

        'If needed, change the SOLIDWORKS configuration to activate the study
        If sStudyConfig <> "" Then
            Part.ShowConfiguration2(sStudyConfig)
        
End If

        StudyMngr = ActDoc.StudyManager
        
If StudyMngr Is Nothing Then ErrorMsg(SwApp, "No study manager object")

        
'Find the study
        bStudyFound = False
        iNumberOfStudies = StudyMngr.StudyCount
        Study =
Nothing
        For ix = 0 To iNumberOfStudies
            StudyMngr.ActiveStudy = ix
            Study = StudyMngr.GetStudy(ix)
            
If Study Is Nothing Then ErrorMsg(SwApp, "Failed to get study: " & ix)
            
If UCase(Study.Name) = UCase(sStudyName) Then
                bStudyFound = True
                Exit For
            End If
        Next
        If bStudyFound = False Then
            ErrorMsg(SwApp, "Failed to find study named: " & sStudyName)
        
End If

        'Create mesh
        CWMesh = Study.Mesh
        
If CWMesh Is Nothing Then ErrorMsg(SwApp, "No mesh object")

        
'Check to use the default element size or tolerance
        If ((el = 0) Or (tl = 0)) Then

            'Get the default element size and tolerance
            Call CWMesh.GetDefaultElementSizeAndTolerance(iMeshUnit, el_hold, tl_hold)

            
'If element size was not entered, use the default
            If el = 0 Then
                el = el_hold
            
End If

            'If tolerance size was not entered, use the default
            tl = 0.025
            
If tl = 0 Then
                tl = tl_hold
            
End If

        End If

        'Create mesh
        If CWMesh.MesherType = swsMesherType_e.swsMesherTypeAlternate Then
            'Using the curvature-based mesher; set the min element size equal to the max element size
            errCode = Study.CreateMesh(0, el, el)
        
Else
            'Using the standard mesher
            errCode = Study.CreateMesh(0, el, tl)
        
End If
        If errCode <> 0 Then ErrorMsg(SwApp, "Failed to create mesh: Error code = " & CStr(errCode))

        
'Check the mesh state
        VerifyLong(swApp, swsMeshState_e.swsMeshStateExistsAndCurrent, CWMesh.MeshState, "Mesh is not current or does not exist")

        
'Check the number of components that failed to mesh
        VerifyLong(SwApp, 0, CWMesh.GetNoOfFailedComponents, "Mesh failure")

        
'Get analysis type
        iStudyType = Study.AnalysisType
        
If iStudyType = swsAnalysisStudyType_e.swsAnalysisStudyTypeStatic Then
            StudyOptions = Study.StaticStudyOptions
        
ElseIf iStudyType = swsAnalysisStudyType_e.swsAnalysisStudyTypeThermal Then
            StudyOptions = Study.ThermalStudyOptions
        
ElseIf iStudyType = swsAnalysisStudyType_e.swsAnalysisStudyTypeFrequency Then
            StudyOptions = Study.FrequencyStudyOptions
        
ElseIf iStudyType = swsAnalysisStudyType_e.swsAnalysisStudyTypeBuckling Then
            StudyOptions = Study.BucklingStudyOptions
        
ElseIf iStudyType = swsAnalysisStudyType_e.swsAnalysisStudyTypeNonlinear Then
            StudyOptions = Study.NonLinearStudyOptions
        
Else
            ErrorMsg(swApp, "Study options for this type of analysis are not available")
        
End If
        If StudyOptions Is Nothing Then ErrorMsg(SwApp, "Failed to get study options object")

        
'Set solver type
        StudyOptions.SolverType = iSolverType

        
'Run analysis
        errCode = Study.RunAnalysis
        
If errCode <> 0 Then ErrorMsg(SwApp, "Analysis failed with error code " & errCode)

        
'Get results
        CWFeatObj = Study.Results
        
If CWFeatObj Is Nothing Then ErrorMsg(SwApp, "Failed to get results object")

        Force = CWFeatObj.GetConnectorForcesWithTimeValue(0.0,
"Counterbore with Nut-1", swsUnit_e.swsUnitSI, accurateTime, errCode)

        
If errCode <> 0 Then ErrorMsg(SwApp, "Failed to get connector results at the specified time")

        Debug.Print(
"Connector forces, moments, and torques for Counterbore with Nut-1 at time, " & accurateTime & ":")
        Debug.Print(
"   Shear force x-component: " & Force(0))
        Debug.Print(
"   Shear force y-component: " & Force(1))
        Debug.Print(
"   Shear force z-component: " & Force(2))
        Debug.Print(
"   Resultant shear force: " & Force(3))
        Debug.Print(
"   Axial force x-component: " & Force(4))
        Debug.Print(
"   Axial force y-component: " & Force(5))
        Debug.Print(
"   Axial force z-component: " & Force(6))
        Debug.Print(
"   Resultant axial force: " & Force(7))
        Debug.Print(
"   Bending moment x-component: " & Force(8))
        Debug.Print(
"   Bending moment y-component: " & Force(9))
        Debug.Print(
"   Bending moment z-component: " & Force(10))
        Debug.Print(
"   Resultant bending moment: " & Force(11))
        Debug.Print("   Torque x-component: " & Force(12))
        Debug.Print(
"   Torque y-component: " & Force(13))
        Debug.Print(
"   Torque z-component: " & Force(14))
        Debug.Print(
"   Resultant torque: " & Force(15))

        
'Check maximum resultant bending moment
        UResMax = 0.467
        Tol1 = 0.1
        
VerifyTolerance(SwApp, UResMax, CDbl(Force(11)), Tol1, "Resultant bending moment is beyond tolerance")

    
End Sub

    Public swApp As SldWorks

End Class

 

 



Provide feedback on this topic

SOLIDWORKS welcomes your feedback concerning the presentation, accuracy, and thoroughness of the documentation. Use the form below to send your comments and suggestions about this topic directly to our documentation team. The documentation team cannot answer technical support questions. Click here for information about technical support.

* Required

 
*Email:  
Subject:   Feedback on Help Topics
Page:   Get Connector Forces, Moments, and Torques at a Time Example (VB.NET)
*Comment:  
*   I acknowledge I have read and I hereby accept the privacy policy under which my Personal Data will be used by Dassault Systèmes

Print Topic

Select the scope of content to print:

x

We have detected you are using a browser version older than Internet Explorer 7. For optimized display, we suggest upgrading your browser to Internet Explorer 7 or newer.

 Never show this message again
x

Web Help Content Version: API Help (English only) 2021 SP05

To disable Web help from within SOLIDWORKS and use local help instead, click Help > Use SOLIDWORKS Web Help.

To report problems encountered with the Web help interface and search, contact your local support representative. To provide feedback on individual help topics, use the “Feedback on this topic” link on the individual topic page.