You can
manually enter measurements results into the CMM report as a comment line, then
automatically import them into CMM Data Import. This way, you can enter manual results
directly into the CMM output file or enter the manual results directly into Measurements
Input.
There are two formats to choose from.
Format 1
.ME Axis marker,Nominal Value,+Tolerance Value,-Tolerance
Value,Results
You define the M.E. Axis marker and
Delimiter in
Text Markers
settings.
Format 2
This format is based on the manual entry from CMM requirements for PPAP Creator.
[item ID, ME, measurement note, specification note, nominal, +tol, -tol,
actual]
You define the beginning marker, blueprint word, M.E. Axis, and End of file
markers in
Text Markers settings.
For example:
[ITEM 6,ME,,2
PLACES,2.00,0.5,0.5,2.03,2.18].
Location |
Description |
1 |
Identifies the item (balloon) number from the drawing.
You must identify this with the word "item" (such as Item 12), or the word you
defined in Text Markers
settings as
a
blueprint identification
marker. |
2 |
Identifies the item as a manual entry
(ME). |
3 |
(Optional.) Identifies notes to include in the
report for the measurement results. |
4 |
(Optional.) Identifies notes to include
regarding the specification and GD&T feature control
frames. |
5 |
(Optional.) Identifies the nominal, and is
reported in the specification column. The value must be
numeric. |
6 |
(Optional.) Identifies the plus tolerance.
Enter the value only, not the + sign. The
value must be numeric. |
7 |
(Optional.) Identifies the minus tolerance.
Enter the value only, not the + sign. The
value must be numeric. |
8 (and subsequent locations) |
(Optional.) Identifies the actual value. Enter
as many actual results as required (for example, if you take
readings in three places, enter all three results). Separate
actual results by commas. The values must be numeric. |