Cooling Time
|
Calculates the total cooling time in seconds as
follows:
Cooling
Time = Filling
Time (Injection Unit
Settings PropertyManager) + Pressure Holding Time (Injection Unit Settings - Pack
tab PropertyManager) + Pure Cooling Time (Injection Unit Settings - Pack tab
PropertyManager)
The Cool simulation solver uses the Cooling Time to calculate
the temperature reduction of the polymer material inside the
mold cavity.
To modify the Cooling Time without affecting the other
preprocess settings, edit the Pure Cooling Time in the Injection Unit Settings - Pack
tab PropertyManager.
|
|
Ejection Temperature
|
Specifies the material's ejection
temperature. |
|
Volume % frozen at
ejection |
Specifies the percentage of the mold's volume that
needs to cool below the material's ejection temperature. Default
value is 90%. The Cool analysis ends when the
specified percentage of the mold's volume falls below the
ejection temperature.
|
|
Exclude Runner from Ejection
Temperature Criteria |
Excludes the cooling state of the sprue and
runner segments from the ejection criteria. It is common to reduce
the overall manufacturing time by ejecting the part before the
sprue and runner segments have cooled completely.
|
|
Flow
Rate / Coolant Temperature Profile
|
Lets you specify a varying flow
rate and coolant temperature during the cooling cycle. Coolant Input
boundary conditions override this data. This
option is available when you select Cooling Time for option Specify control based
on.
|
|
Reset All
|