Places the selections so that they share the same
centerline. To prevent rotation in concentric
mates, after selecting the mating geometry, select Lock rotation.
This option is selected automatically if
you have Lock rotation of new
concentric mates to Toolbox components
selected in the Hole
Wizard/Toolbox system options.
If you have components with two holes, you can
mate those components even when the holes are not the same
distance apart by creating a misaligned mate. Select a
misalignment type:
Align this mate
|
Solves the
first concentric mate exactly, and applies all the
misalignment to the linked concentric
mate. |
Align Linked
mate |
Solves the
linked concentric mate exactly, and applies all
the misalignment to the first concentric
mate. |
Symmetric
|
Applies
half of the misalignment to each concentric
mate. |
Specify the Maximum deviation
value if you do not want to use the value defined in the
document property. To change the Maximum deviation value, clear
the Use Document
Property option.
The
Result section lists
the misaligned mates, where the mates are symmetric misaligned
mates or
only one of the mates is misaligned.
When using misaligned concentric mates, click
Remove link between
mates to revert the concentric mate.
The misaligned mates appear in a Misaligned folder under the
Mates
folder.
|