Adds a uniform base excitation to all locations restrained in the specified directions for dynamic studies.
.NET Syntax
Visual Basic (Declaration) | |
---|
Function AddUniformBaseExcitation2( _
ByVal NType As System.Integer, _
ByVal DirectionEntity As System.Object, _
ByVal NUnits As System.Integer, _
ByVal BDir1 As System.Boolean, _
ByVal DVal1 As System.Double, _
ByVal BDir2 As System.Boolean, _
ByVal DVal2 As System.Double, _
ByVal BDir3 As System.Boolean, _
ByVal DVal3 As System.Double, _
ByRef ErrorCode As System.Integer _
) As CWBaseExcitation |
Visual Basic (Usage) | |
---|
Dim instance As ICWLoadsAndRestraintsManager
Dim NType As System.Integer
Dim DirectionEntity As System.Object
Dim NUnits As System.Integer
Dim BDir1 As System.Boolean
Dim DVal1 As System.Double
Dim BDir2 As System.Boolean
Dim DVal2 As System.Double
Dim BDir3 As System.Boolean
Dim DVal3 As System.Double
Dim ErrorCode As System.Integer
Dim value As CWBaseExcitation
value = instance.AddUniformBaseExcitation2(NType, DirectionEntity, NUnits, BDir1, DVal1, BDir2, DVal2, BDir3, DVal3, ErrorCode) |
Parameters
- NType
- Type of excitation as defined in swsBaseExcitationType_e
- DirectionEntity
- Face, edge, or plane of direction for the excitation; null for global direction if Response Spectrum study
- NUnits
If NType is ... |
Then units are as defined in ... |
swsBaseExcitationType_e.swsBaseExcitationType_Displacement |
swsLinearUnit_e |
swsBaseExcitationType_e.swsBaseExcitationType_Velocity |
swsVelocityUnit_e |
swsBaseExcitationType_e.swsBaseExcitationType_Acceleration |
swsAccelerationUnit_e |
- BDir1
- -1 or true to add excitation along plane direction 1, 0 or false to not; valid only if DirectionEntity is a face, plane, or unspecified
- DVal1
- Excitation along plane direction 1; valid only if BDir1 = -1 and DirectionEntity is a face, plane, or unspecified (see Remarks)
- BDir2
- -1 or true to add excitation along plane direction 2; 0 or false to not; valid only if DirectionEntity is a face, plane, or unspecified
- DVal2
- Excitation along plane direction 2; valid only if BDir2 = -1 and DirectionEntity is a face, plane, or unspecified (see Remarks)
- BDir3
- -1 or true to add excitation along normal to the plane or along an edge; 0 or false to not; valid only if DirectionEntity is a face, edge plane, or unspecified
- DVal3
- Excitation along normal to the plane or along an edge; valid only if BDir3 = -1 and DirectionEntity is a face, edge, plane, or unspecified (see Remarks)
- ErrorCode
- Error code as defined in swsRestraintError_e
Return Value
ICWBaseExcitation
Example
Remarks
See Also
Availability
SOLIDWORKS 2022 FCS, Revision Number 30