You use the Properties dialog box to modify data
associated with the title block.
If the title block already exists, the left side of the dialog box displays a preview of
the edit mode (with attributes). If you have selected several title blocks, only the
common properties are displayed.
To access the title block properties, click
.
General
Option |
Description |
Title |
Defines the title block title. This title must be
unique. |
Description |
Defines a text description in all languages
managed in the software. This is displayed under the miniature in
the thumbnail mode. The description is available in all languages by
clicking the specific icon. The language selector opens allowing you
to select the languages you want. |
Class |
Defines the class where the title block is
stored. |
Unit System |
Defines the title block mode. This choice is
important. The title block and the scheme created in the drawing
from this title block must use the same unit system. When you create
a new title block, SOLIDWORKS Electrical uses the template file
corresponding to the unit system you selected. |
Library |
Defines the library where the title block is
stored. |
System
Option |
Description |
Creator |
Displays the origin of the object:
- System. The object is provided with
the software installation.
- User. The object is created by a
user.
- Modified system. The object is
provided with the software installation and has been
modified by the user.
|
Created By |
Displays the name of the user who created the
object. |
Creation Date |
Displays the creation date of the object. |
Modified By |
Displays the name of the user who modified the
object. |
Modification Date |
Displays the modification date of the
object. |
Rows
Option |
Description |
With rows |
Activates row management in the title
block. |
Mark of first row |
Lets you mark the first row. The following rows
are marked automatically. |
First row position |
Lets you enter the Y coordinate of the first
row. |
Height of row |
Defines the row height. If the first row is on top
of the title block and the last row is on the bottom, place the sign
"-" before the value. All rows must have the same height. |
Number of rows |
Defines the number of rows in the title
block. |
Row numbering |
When the title block has more than one column,
select the mode to use. |
Columns
Option |
Description |
With columns |
Activates column management in the title
block. |
Mark of first
column |
Lets you mark the first column. The following
columns are marked automatically. |
First column
position |
Lets you enter the X coordinate of the first
column. |
Width of column |
Defines the column width. All columns must have
the same width. |
Number of column |
Defines the number of columns in the title
block. |
Options
Option |
Description |
Cross references
offset |
Defines the cross references thumbnail insertion
height for Parent in table type
symbols. |
Scale |
Defines the scale factor assigned to the elements
inserted in the drawing. This parameter is used for drawings in 2D
layouts. |