Subject the rectangular plate (0.01 m x 0.001 m) to zero flux at its
left-hand end, constant temperature of 0 °C at its right-hand end, uniform initial temperature
followed by a step change to constant internal heat generation. Determine the temperature at x =
0.005 m.

In the model, T = 0 °C everywhere at time = 0 and internal heat
generation for time t > 0 = 107(1 + 0.005 t).
File Name
|
Open drive
letter:\Users\Public\Public Documents\SOLIDWORKS\SOLIDWORKS
version\samples\Simulation
Examples\Verification\NAFEMS_Thermal_Test8.SLDPRT.
|
Study Type
|
Thermal (transient thermal analysis)
|
Shell Parameters
|
Shell thickness = 1 m - Thick shell formulation
|
Mesh Size
|
Set Global Size to 0.0005 m.
|
Material Properties
|
- Thermal Conductivity (K)
= 52 W/mK
- Specific Heat (C) = 460
J/kgK
- Density (ρ) = 7850
kg/m3
|
Results
Define a Workflow
Sensitive sensor at the target location, and use the
Probe tool to list the temperature for time t = 2
sec.
|
NAFEMS |
SOLIDWORKS
Simulation |
Target location |
t = 2 sec |
|
x = 0.005m |
3.81 °C |
3.78 °C |
Reference
NAFEMS Publication P16, The International Association
for the Engineering Analysis Community, " Benchmark Tests for Thermal Analysis", Test 8,
YR3087, VOL. 2, 1986.