Running the Optimization Design Study

You run the Design Study to minimize the mass and find the optimal model dimensions that satisfy the constraint.

  1. On the Results View tab, select an iteration highlighted in red, for example Iteration 1.
    Iterations that do not satisfy the constraints are highlighted in red. Here, FOS < 2.
    Parameters Iteration 1
    Rib_Thickness 4 mm
    Cut_Depth 10 mm
    Cyl_Ht 13 mm
    Cut_Diameter 5.5 mm
    FOS 1.985
    Mass1 35.447g
  2. Select the Optimal column highlighted in green.
    The study updates the body to correspond to the optimal variables in the graphics window.
  3. Review the Optimal column.
    Parameters Optimal
    Rib_Thickness 3.91 mm
    Cut_Depth 9.9 mm
    Cyl_Ht 11 mm
    Cut_Diameter 8.72 mm
    FOS 2.008
    Mass1 33.305 g

    The initial mass of the knob was 49.8092 g. The optimal mass of the knob is now 33.305 g, a reduction of 33%.

Congratulations! You have completed this tutorial.