Setting a Constant Amplitude Fatigue Event

You define a fatigue event of 20,000 load cycles that is based on the Ready_Static study.

  1. In the fatigue study tree, right-click Loading (-Constant Amplitude-) and click Add Event.
  2. In the PropertyManager:
    • For Cycles noofcycles.png type 20000.
    • In Loading Type loadingtype.png select Zero based (LR = 0).
    • Click .
    Simulation creates an Event-1 icon in the Loading folder. During each loading cycle, the loads, and hence stress components, of the reference static study change magnitudes from their maximum values to zero.

    As a reference study for a fatigue event, you can select a static study, or stress results from a particular solution step of a nonlinear study or time history linear dynamic study.