Defining Variable-Amplitude Loading Event

You define a variable-amplitude fatigue loading event based on the static study you performed earlier on the model.

  1. In the Fatigue_study tree, right-click Loading (-Variable Amplitude-) and select Add Event .
  2. In the PropertyManager, under Load, click Get Curve.
  3. In the Load History Curve dialog box, click Get curve.
  4. Browse to the installation folder of the Function Curve Library (*.cwcur) named sample sae curves.cwcur.
    See Simulation > CWLang > English for the installation location of the Function Curve Library.
  5. In the Function Curves dialog box, under Load History Curve, select SAE Suspension, and click OK.
    The curve is loaded.
    The first amplitude of the curve is -999 and the mean is negative. The Gerber method will be used to account for the mean stress correction as specified in the properties of the study.
  6. In the Load History Curve dialog box, click OK.
    The first amplitude in the time history is -999. Suppose that this value corresponds to a total bearing load of 12,000 lbs (twice the total bearing load applied in the static study). The scale factor (SF) in the next step should be calculated as: SF = (12000/6000)(1/-999)=-0.0020
  7. In the Add Event (Variable) PropertyManager under Study, select the Ready_Static and set the Scale associated with the static study to -0.002.
    The program scales the stresses in the same way. For example, the maximum von Mises stress associated with fatigue loading amplitude A is equal to (-0.002)(A)(S), where S is the stress associated with the static study at a location.
  8. Under Option, set Number of repeats to 1.
  9. Click .