To use a Pressure Vessel Design study:
- Run the static studies that you want to combine.
- Right-click the model name in the Simulation study tree and select Study.
- In the PropertyManager, click Pressure Vessel Design
then click
.
- Right-click Setup to access the Result Combination Setup PropertyManager.
Select the studies that you want to combine and apply a factor for each study if you select Linear Combination.
- Right-click the study and select Run.
The software combines the results of the selected studies. You can view default plots or create new plots.