Saving Results at All Solution Steps

To save results at all solution steps:

  1. Right-click the Result Options folder, and select Edit/Define.
  2. Under Save Results, select For all solution steps.
  3. For linear dynamic studies only, under Quantity check the desired quantities to save their results.
  4. For linear dynamic studies only, under Mode Selection, do the following:
    1. Click Selected modes.
    2. Click Edit.
    3. In Mode Selection Filter, under Mode No, uncheck the modes you do not want to include in the solution.
    4. Click OK.
  5. Click .