Restraining the Model in the Radial Direction

The outer faces of the chamber are restrained in the radial direction.

  1. In the Simulation study tree, right-click the Fixtures icon and select Advanced Fixtures.
  2. In the PropertyManager, do the following:
    1. Under Advanced (Use Reference Geometry), select On Cylindrical Faces.
    2. In the graphics area, click the cylindrical face of the groove as shown in the figure.
    3. Under Translations, click Radial and make sure that 0 appears in the value box.
    4. Click PM_OK.gif.