Setting the Result Options You set the solution time after impact and the locations for time history response graphs. In the Simulation study tree, right-click Result Options and select Define/Edit, or click Result Options (Simulation toolbar). In the PropertyManager, type 45 (microseconds) for Solution Time After Impact . The default value is calculated by the program from 3L/Ve, where L is the largest model box size and Ve is the speed of the elastic wave in the material. Ve is calculated as the square root of (modulus of elasticity/Density). The program internally calculates appropriate time steps that can be nonuniform. Under Save Results: Type 0 for Save Results Starting From . Set No. of Plots to 30. Select <Ready> - Drop Test for Sensor List . Click . Parent topicImpact of an Aluminum Bar on a Rigid Boundary Previous topic Setting up the Drop Test Study Next topic Meshing the Model and Running the Analysis