Viewing the Results of the Ready Study

The sample part includes a Ready study for you to run. It is good practice to run the initial studies to get an estimate of the results and to verify that no build errors exist.

  1. Click the Ready study, then Run (Simulation CommandManager).
  2. In the Simulation study tree, open the Results folder.
  3. Double-click Stress1 (-vonMises-) to display the vonMises stress plot.
    The units are N/mm^2 (MPa).