You define a local contact pair with friction between the slider and the locker.
-
In the Simulation study tree, right-click Connections
and select Local Interaction
.
-
In the PropertyManager, under Interaction, select Manually select
local interactions.
-
Under Type, select
Contact.
-
Click in Faces, Edges, Vertices for
Set 1
, then select the face of the
slider shown in the figure.
-
Click in Faces for Set 2
, then select the face of the
locker shown in the figure.
-
Select Coefficient of
friction and accept the default value of 0.05.
-
Under Advanced, select Node to
surface, for contact formulation.
-
Click
.
The local contact interaction is applied.