The stress plot shows that the CrankPulley-1 part has low stresses. Next, you exclude the CrankPulley-1 part from analysis and rerun the study.
-
Click the down arrow on Results
Advisor
(Simulation CommandManager)
and select Model Only (No Results).
- In the Simulation study tree, right-click crankpulley-1 and select Exclude from Analysis
.
Fixed-1 is suppressed because a required face from the CrankPulley is now excluded from the analysis.
- If a confirmation dialog box appears, click Yes to confirm.
Warnings still exist because the mesh and the plots are out of date.
- In the FeatureManager design tree, right-click crankpulley-1 and select Hide Components
.