Viewing Results In the Simulation study tree, right-click Fixtures and select Hide All to hide the restraint symbols. Right-click External Loads and select Hide All to hide the load symbols. Open the Results folder. Double-click Stress1 (-vonMises-) to display the plot. If the plot does not exist, create the plot using one of the methods in steps 5, 6, or 7. Optional: To add a plot: Right-click the Results folder and select Define type of plot Plot. Set the options in the PropertyManager and click . Optional: To add a von Mises stress plot using English units for a static study: Right-click the Results folder and select Define Stress Plot . Under Display, select VON: von Mises Stress in Component . Under Display, select psi in Units . Click . Optional: To add a thermal plot displaying temperature in Celsius for a thermal study: Right-click the Results folder and select Define Thermal Plot . Under Display, select TEMP: Temperature in Component . Under Display, select Celsius in Units . Click . Right-click the plot icon and select Edit Definition. In the PropertyManager under Display, set Units to psi and click . Parent topicStatic Analysis of an Assembly Previous topic Meshing the Assembly Next topic Excluding a Component from Analysis