Air vents allow air to escape from a cavity as the melted polymer fills
the
mold.
Without enabling
Venting Analysis,
the software assumes that the displaced air has the means to vent (mold is adequately
vented). With
Venting Analysis enabled, you can
predict the effect of the displaced air on the plastic filling. You use the
Air Vents boundary condition to specify venting
locations.
By adding air vents in critical locations of a cavity, you can
avoid potential defects of plastic parts because of the diesel effect. You can
apply air vents to Cavity and Cold Runner System domains.
To open the Air
Vents PropertyManager:
- In the PlasticsManager, right-click , and click Air Vents
.
Specify Locations
 |
Edges or Points
|
Selects edges or points (vertices or sketch points) of a model that
correspond to air vents. Selected entities appear in blue in the
graphics area.
|
To run Venting Analysis after setting
the vent locations, in the Fill Settings
PropertyManager, select Venting Analysis.
After running the analysis, you can view the results in the Fill Results PropertyManager, under Venting Pressure.