Result Options
The Result Options PropertyManager
allows you to set options for the results for linear dynamic and nonlinear
studies.
Save Results
For all solution
steps. When checked, the program saves the results at all solution
steps.
For specified
solution steps. When checked, the program saves the results at
solution steps specified in sets.
Quantity
Appears for linear dynamic studies only. Results of the following quantities
are saved when selected:
Note: Acceleration
quantities are always absolute. Nonlinear dynamic studies always save
relative displacements and velocities.
Solution Steps - Set 1
Appears if For specified solution steps
is selected.
Start.
The first solution step number.
End. The
last solution step number.
Increment.
Solution step increment.
Solution Steps - Set 2
Appears if Solution Steps - Set 1
is selected. You can specify up to five sets.
Locations for Graphs
Appears if For specified solution steps
is selected. Select vertices and reference points to save the results.
Results are saved at every solution step.
If you do not select at least one entity,
the results are saved for all nodes.
Mode Selection
Appears for linear dynamic studies only.
To select modes:
Click Edit.
The Mode
Selection Filter dialog appears.
Under Mode
No, uncheck
the modes that you do not want to include in the solution.
Click OK.
To save results at all solution steps:
Right-click the Result
Options folder, and select Edit/Define.
Under Save Results,
select For all solution steps.
For linear dynamic studies only, under Quantity
check the desired quantities to save their results.
For linear dynamic studies only, under Mode
Selection, do the following:
Click Selected
modes.
Click Edit.
In Mode
Selection Filter, under Mode No,
uncheck the
modes you do not want to include in the solution.
Click OK.
Click
.
To save results at specified solution steps:
Right-click the Result
Options folder, and select Edit/Define.
Under Save Results,
select For specified solution steps.
For linear dynamic studies only:
For linear dynamic studies only, under Quantity,
check the desired quantities to save their results.
Under Solution
Steps - Set1, set the first solution step number Start,
the last solution step number End,
and the solution step increment Increment.
Under Locations
for Graphs, select a workflow sensitive
simulation data sensor where data will be saved to plot response graphs.
For linear dynamic studies only, under Mode
Selection, select All modes to include all available normal
modes in the solution.
Click
.
Related Topics
Setting
the Properties of the Nonlinear Analysis
Performing
Nonlinear Analysis
Performing
Linear Dynamic Analysis.