Simulation Data Sensors

Use Simulation Data sensors to monitor the following:

  • Simulation data such as stresses, connector forces, and factors of safety on particular regions of the model

  • Results from Simulation transient studies such as nonlinear, dynamic, drop-test studies, and design scenarios. Use Workflow Sensitive sensors to plot graphs on specific locations for transient and design studies.

  • Trend Tracker data graphs

  • Goals and Constraints for Design Studies

Sensor Type

Simulation Data. Monitor Simulation results.

See Sensors PropertyManager for information on other sensor types.

Data Quantity

Select the result quantity and component to track with a sensor.

Results

Component

Plane, Axis or Coordinate System

Stress

Stress components

Select a plane, axis or coordinate system for reference geometry.

Strain

ESTR: Equivalent Strain

 

Displacement

Displacement components

 

Frequency

Selected mode shape

 

Buckling

Load factor for selected buckling mode shape

 

Connector Force

Axial, Shear and Bending Resultant forces

 

Free-Body Forces

Free body forces

 

Acceleration

Acceleration components

 

Velocity

Velocity components

 

Thermal

Thermal components

 

Workflow Sensitive

Result components on particular locations

 

Properties

Unit

Select the units for the Simulation quantity

Criterion.

Select the variable to monitor.

Step Criterion

  • Across All Steps

Tracks the Simulation data value across all steps for the entire model or for the selected entities and reports a single value. For example, if you select Model Max for Criterion, the sensor reports the maximum value in the model across all steps.

  • At Specific Plot Step

Tracks the Simulation data value at the specified plot step based on the plot number you specify. You can control the number of plot steps and step interval using the Result Options folder in the Simulation study tree.

  • At Specific Mode Shape

This option is available only for the frequency and buckling sensors. Specifies the mode number at which the sensor tracks the result.

Select Components , Bodies, Faces, Edges, or Vertices

Values are monitored over these selected entities.

Connectors.

Available only when connectors are defined and Connector Force is selected under Data Quantity.

  • All pins

  • All bolts

  • All bearings

  • Individual connector

Select a vertex or a point.

Available when Workflow Sensitive is selected under Data Quantity.

Select vertices or reference points to graph time history plots for Simulation transient studies.

 

Link to selection.

Check this option to automatically update the selected vertices or points coordinates when geometry changes.

Location(s)

Available when Workflow Sensitive is selected and Link to selection is cleared. Lists the points and coordinates of the sensor locations.

Unit

Set the display units for the Location(s) list.

Factor of Safety

Select the Factor of Safety to monitor the value of factor of safety (FOS).

  • Use limit strength in material data. (Available for Stress components only.) Uses yield strength data defined in the Material dialog box.

  • Enter limit value. (Available for all Simulation results except Stress.) Enter the upper limit value for the monitored quantity. For example, the maximum resultant displacement of the model is calculated to URES = 2 inches. You enter 5 in limit value. The sensor calculates the FOS for the maximum URES as 5/2 =2.5.

Alert

Select Alert and set an operator and limits.

Alerts notify you immediately when the sensor value deviates from the limits you specify. When a sensor triggers an alert, the system beeps and the sensor is flagged in the FeatureManager design tree.

File Options

  • Save. Saves the sensor coordinates to a comma delimited *.csv file. Use a text editor or Microsoft Excel to view this file.

  • Import. Imports sensor locations from a *.csv or *.txt file as a new sensor.

Related Topics

Defining Sensors

Probe Results



Provide feedback on this topic

SOLIDWORKS welcomes your feedback concerning the presentation, accuracy, and thoroughness of the documentation. Use the form below to send your comments and suggestions about this topic directly to our documentation team. The documentation team cannot answer technical support questions. Click here for information about technical support.

* Required

 
*Email:  
Subject:   Feedback on Help Topics
Page:   Sensors
*Comment:  
*   I acknowledge I have read and I hereby accept the privacy policy under which my Personal Data will be used by Dassault Systèmes

Print Topic

Select the scope of content to print:

x

We have detected you are using a browser version older than Internet Explorer 7. For optimized display, we suggest upgrading your browser to Internet Explorer 7 or newer.

 Never show this message again
x

Web Help Content Version: SOLIDWORKS 2012 SP05

To disable Web help from within SOLIDWORKS and use local help instead, click Help > Use SOLIDWORKS Web Help.

To report problems encountered with the Web help interface and search, contact your local support representative. To provide feedback on individual help topics, use the “Feedback on this topic” link on the individual topic page.