Hide Table of Contents

Cool Pipe PropertyManager

The Cool Pipe PropertyManager sets the parameters of the cooling channels created from a sketch using the Solid Mesh Procedure > Runner and Cooling System Design.

To open the Cool Pipe PropertyManager:

  • In the Plastics manager, expand Boundary Conditions, and double-click Cool Pipe.
With this boundary condition you can define one inlet and one outlet for each cooling circuit. All other side passages are treated as dead ends.
  • By creating a sketch to define the cooling channel layout, and entering channel diameters using the Channel Design PropertyManager, you get more accurate COOL analysis results (such as part cooling time, and part and mold temperatures at end of cooling).
  • If your cooling system is created from solid geometry, use the Coolant Entrance boundary condition instead of Cool Pipe.

Coolant velocity that is high enough to create turbulent flow is essential to create maximum heat transfer from the mold into the coolant. The heat transfer coefficient used with Cool Pipe depends on velocity through the Reynolds number, so it is sensitive to Laminar and Turbulent flow conditions.

A warning message will appear in the log and Report text file, if the coolant flow rate is insufficient to maintain turbulent conditions, for example:

** Warning D3001 **  Channel elm. #  1 Reynolds Number=1.0e+002 is less than 4000.

Selections

Lists all cooling channels you previously defined using the Channel Design PropertyManager. To edit the parameters of a cooling channel, select it in the table.

  Inlet Outlet Opening (Elements) Lists the inlet (blue arrow) and outlet elements (red arrow) of the cooling channel.
  Reverse Flow Reverses the coolant flow direction.
  Coolant Material Select a coolant material from the material database.
  Inlet Temperature Sets the temperature of the coolant material at the inlet.

This temperature value overrides the default Min Coolant Temperature in the Cool Settings PropertyManager.

  Flow Parameters Sets the flow control rate of the cooling material within the cooling channel. Select one of the flow parameters input:
  • Flow rate (cc/sec)
  • Total Pressure Drop (MPa)
  Apply Applies the current settings to the cooling channel.


Provide feedback on this topic

SOLIDWORKS welcomes your feedback concerning the presentation, accuracy, and thoroughness of the documentation. Use the form below to send your comments and suggestions about this topic directly to our documentation team. The documentation team cannot answer technical support questions. Click here for information about technical support.

* Required

 
*Email:  
Subject:   Feedback on Help Topics
Page:   Cool Pipe PropertyManager
*Comment:  
*   I acknowledge I have read and I hereby accept the privacy policy under which my Personal Data will be used by Dassault Systèmes

Print Topic

Select the scope of content to print:

x

We have detected you are using a browser version older than Internet Explorer 7. For optimized display, we suggest upgrading your browser to Internet Explorer 7 or newer.

 Never show this message again
x

Web Help Content Version: SOLIDWORKS Plastics 2017 SP05

To disable Web help from within SOLIDWORKS and use local help instead, click Help > Use SOLIDWORKS Web Help.

To report problems encountered with the Web help interface and search, contact your local support representative. To provide feedback on individual help topics, use the “Feedback on this topic” link on the individual topic page.