Coolant Flow Field PropertyManager

The Coolant Flow Field Boundary Condition allows you to define multiple inlets and outlets for complex cooling circuits. All side passages without inlets or outlets are considered dead ends.

To open the Coolant Flow Field PropertyManager:

  • In the PlasticsManager, expand Boundary Conditions, and double-click Coolant Entrance.

Coolant Flow Field

  Gravity Direction: (Global) Select the downward direction for gravity X dir, Y dir, or Z dir.
  Control type Select one of the following value for your control type

Flow rate (cc/sec)

Enter the coolant flow rate.

Coolant velocity that is high enough to create turbulent flow is essential to create maximum heat transfer from the mold into the coolant. A warning message is written to the log file if the coolant flow rate is too low to support turbulent conditions.

Pressure drop

Enter the pressure drop between the inlet and outlet.

  Inlet Temperature (ºC) Set the coolant temperature at the inlet.
  Apply Adds the current cooling circuit definition in the table.
  Clear Removes the selected cooling circuit definition from the table.
  Set Inlet and Outlet Defines the inlet(s) and outlet(s) in each cooling circuit. Select a circuit from the table and use the dialogs to define its inlets and outlets.

Inlet

Sets the selected cooling circuit as an inlet.

Outlet

Sets the selected cooling circuit as an outlet.

  Select through Selects all visible and hidden surfaces within your selection window. Clear the box to select visible surfaces only.
  Select Saves the current definition.
  Delete Clears the current definition.


Provide feedback on this topic

SOLIDWORKS welcomes your feedback concerning the presentation, accuracy, and thoroughness of the documentation. Use the form below to send your comments and suggestions about this topic directly to our documentation team. The documentation team cannot answer technical support questions. Click here for information about technical support.

* Required

 
*Email:  
Subject:   Feedback on Help Topics
Page:   Coolant Flow Field PropertyManager
*Comment:  
*   I acknowledge I have read and I hereby accept the privacy policy under which my Personal Data will be used by Dassault Systèmes

Print Topic

Select the scope of content to print:

x

We have detected you are using a browser version older than Internet Explorer 7. For optimized display, we suggest upgrading your browser to Internet Explorer 7 or newer.

 Never show this message again
x

Web Help Content Version: SOLIDWORKS Plastics 2017 SP05

To disable Web help from within SOLIDWORKS and use local help instead, click Help > Use SOLIDWORKS Web Help.

To report problems encountered with the Web help interface and search, contact your local support representative. To provide feedback on individual help topics, use the “Feedback on this topic” link on the individual topic page.