Using Specific Symbols in Configurations of Terminal Strip Drawings

To use specific symbols in terminal strip drawings, in the Terminal Strip Drawing configuration, you must activate Insert custom symbol and define its parameters.

This feature is not applicable in DIN configurations.

To update the configuration of terminal strip drawings:

  1. In the Documents tab, right-click the Project and select Configurations > Terminal strip drawing.
  2. Select the configuration file and click .
  3. In the Symbols tab, select Insert custom symbol.
  4. Define in a first step the parameters for Priority - Terminal type / Terminal symbol and in a second step the parameters for Priority - Manufacturer part / symbol.
    The changes will be applied for the next update of the terminal strip drawings.