Welcome
Expand Getting StartedGetting Started
Expand SOLIDWORKS API HelpSOLIDWORKS API Help
Collapse SOLIDWORKS Electrical API HelpSOLIDWORKS Electrical API Help
Expand Getting StartedGetting Started
Expand Release NotesRelease Notes
Collapse ClassesClasses
Expand Class ListClass List
Class Index
Collapse Class HierarchyClass Hierarchy
_DIEwProjectXEvents
Collapse IDispatchIDispatch
IEwAddIn
IEwAPIX
IEwApplicationReactorX
IEwApplicationSettingsX
IEwApplicationX
IEwArchiveEnvironmentX
IEwCableCoreX
IEwCableReferenceManagerX
IEwCableReferenceX
IEwCommandContextX
IEwCommandManagerX
IEwCommandX
IEwDialogAlignPartsParametersSelectorX
IEwDialogLocationSelectorX
IEwDialogMacroSelectorX
IEwDialogManufacturerPartOrderingX
IEwDialogManufacturerPartSelectorX
IEwDialogProgressX
IEwDialogProjectManagerX
IEwDialogResumeX
IEwDialogSummaryX
IEwDialogTaskX
IEwDockingPaneManagerX
IEwDockingPaneX
IEwEnvironmentX
IEwInteropFactoryX
IEwLibraryManagerX
IEwLibraryX
IEwLockStringX
IEwManufacturerPartCircuitX
IEwManufacturerPartManagerX
IEwManufacturerPartTerminalX
IEwManufacturerPartX
Collapse IEwObjectBaseXIEwObjectBaseX
IEwPointX
IEwProjectAutomaticArrowsX
IEwProjectBookManagerX
IEwProjectCableManagerX
IEwProjectComponentManagerX
IEwProjectComponentTerminalX
IEwProjectEntity3DManagerX
IEwProjectExcelAutomationX
IEwProjectExportDWGFilesX
IEwProjectExportPDFX
IEwProjectExportPDMX
IEwProjectExportReportX
IEwProjectFileManagerX
IEwProjectFolderManagerX
IEwProjectFunctionManagerX
IEwProjectGenerateTSDrawingX
IEwProjectHarnessManagerX
IEwProjectInputOutputManagerX
IEwProjectLocationManagerX
IEwProjectManagerX
IEwProjectManufacturerPartCircuitX
IEwProjectManufacturerPartManagerX
IEwProjectManufacturerPartTerminalX
IEwProjectManufacturerPartX
IEwProjectNumberDocumentsX
IEwProjectNumberMarksX
IEwProjectNumberWiresX
IEwProjectOptimizeWireOrderX
IEwProjectPrintConfigManagerX
IEwProjectReportManagerX
IEwProjectSnapshotManagerX
IEwProjectSnapshotX
IEwProjectSymbolManagerX
IEwProjectUpdateReplaceDataX
IEwProjectWireManagerX
IEwProjectX
IEwResumeRowX
IEwRibbonControlX
IEwRibbonGroupX
IEwRibbonTabX
IEwRibbonX
IEwRightsManagerX
IEwSymbolCircuitX
IEwSymbolFiltersX
IEwSymbolManagerX
IEwSymbolPointX
IEwSymbolX
IEwTitleBlockManagerX
IEwTitleBlockX
IEwXLSBookX
IEwXLSSheetX
Expand Class MembersClass Members
Expand SOLIDWORKS PDM Professional API HelpSOLIDWORKS PDM Professional API Help
Expand FeatureWorks API HelpFeatureWorks API Help
Expand SOLIDWORKS Costing API HelpSOLIDWORKS Costing API Help
Expand SOLIDWORKS Document Manager API HelpSOLIDWORKS Document Manager API Help
Expand SOLIDWORKS Routing API HelpSOLIDWORKS Routing API Help
Expand SOLIDWORKS Simulation API HelpSOLIDWORKS Simulation API Help
Expand SOLIDWORKS Sustainability API HelpSOLIDWORKS Sustainability API Help
Expand SOLIDWORKS Toolbox API HelpSOLIDWORKS Toolbox API Help
Expand SOLIDWORKS Utilities API HelpSOLIDWORKS Utilities API Help
Expand eDrawings API HelpeDrawings API Help
Expand DraftSight API HelpDraftSight API Help
Expand Lisp Programming BasicsLisp Programming Basics
Expand Lisp Functions OverviewLisp Functions Overview
Expand Lisp Functions ReferenceLisp Functions Reference
Expand Visual Lisp Compatible FunctionsVisual Lisp Compatible Functions
Hide Table of Contents
SOLIDWORKS Electrical API  2021.0.0
Electrical API
IEwProjectCableX Interface Reference

Use this interface to manage a cable inside a project. More...

Inheritance diagram for IEwProjectCableX:

Public Member Functions

EwErrorCode setLength (DOUBLE dLength)
 
BSTR getArticleNumber (EwErrorCode *errorCode)
 Get the article number. More...
 
EwErrorCode setArticleNumber (BSTR strArticleNumber)
 Set the article number. More...
 
BSTR getManufacturer (EwErrorCode *errorCode)
 Get the manufacturer of the cable. More...
 
BSTR getReference (EwErrorCode *errorCode)
 Get the reference of the cable. More...
 
LONG getCoreCount (EwErrorCode *errorCode)
 Get cable core count. More...
 
EwErrorCode setCoreStubs (LONG nCoreIdx, DOUBLE dStubLengthFrom, DOUBLE dStubLengthTo)
 Set lengths of cable core stubs. More...
 
BSTR getExternalID (EwErrorCode *errorCode)
 Get external identifier of this cable. More...
 
EwErrorCode setExternalID (BSTR strExternalID)
 Set the external identifier of this cable. More...
 
BSTR getLinearMass (EwErrorCode *errorCode)
 Get the linear mass (density) of this cable. More...
 
EwErrorCode setLinearMass (BSTR strLinearMass)
 Set the linear mass (density) of this cable. More...
 
EwErrorCode setHarnessID (long lHarnessID)
 Set the Harness ID of this cable. More...
 
LONG getHarnessID (EwErrorCode *errorCode)
 Get the Harness ID associated with the current cable. More...
 
DOUBLE getVoltageDrop (EwErrorCode *errorCode)
 Get the voltage drop associated with the current cable. More...
 
EwErrorCode setVoltageDrop (DOUBLE dVoltageDrop)
 Set the voltage drop associated with the current cable. More...
 
EwErrorCode setFamily (BSTR strFamily)
 Set the family associated with the current cable. More...
 
BSTR getFamily (EwErrorCode *errorCode)
 Get the family associated with the current cable. More...
 
EwErrorCode setSupplierName (BSTR strSupplierName)
 Set the supplier name associated with the current cable. More...
 
BSTR getSupplierName (EwErrorCode *errorCode)
 Get the supplier name associated with the current cable. More...
 
EwErrorCode setStockNumber (BSTR strStockNumber)
 Set the stock number associated with the current cable. More...
 
BSTR getStockNumber (EwErrorCode *errorCode)
 Get the stock number associated with the current cable. More...
 
EwErrorCode set3dOrigin (BSTR str3dOrigin)
 Set the 3D Orign associated with the current cable. More...
 
BSTR get3dOrigin (EwErrorCode *errorCode)
 Get the 3D Orign associated with the current cable. More...
 
EwErrorCode set3dDestination (BSTR str3dDestination)
 Set the 3D Destination associated with the current cable. More...
 
BSTR get3dDestination (EwErrorCode *errorCode)
 Get the 3D Destination associated with the current cable. More...
 
EwErrorCode setStandard (BSTR strStandard)
 Set the standard associated with the current cable. More...
 
BSTR getStandard (EwErrorCode *pErrorCode)
 Get the standard associated with the current cable. More...
 
EwErrorCode setAppliedVoltage (DOUBLE dAppliedVoltage)
 Set the applied voltage associated with the current cable. More...
 
DOUBLE getAppliedVoltage (EwErrorCode *errorCode)
 Get the applied voltage associated with the current cable. More...
 
EwErrorCode setFullLoadCurrent (DOUBLE dFullLoadCurrent)
 Set the full load current associated with the current cable. More...
 
DOUBLE getFullLoadCurrent (EwErrorCode *errorCode)
 Get the full load current associated with the current cable. More...
 
EwErrorCode setInRushFactor (DOUBLE dInRushFactor)
 Set the rush factor associated with the current cable. More...
 
- Public Member Functions inherited from IEwProjectTagObjectX
EwErrorCode setUserData (LONG nUserDataNumber, BSTR strValue)
 Set user data of the object. More...
 
BSTR getUserData (LONG nUserDataNumber, EwErrorCode *errorCode)
 Get user data of the object. More...
 
EwErrorCode setTranslatedData (LONG nUserDataNumber, BSTR strLanguage, BSTR strValue)
 Set the value of a translated text. More...
 
BSTR getTranslatedData (LONG nUserDataNumber, BSTR strLanguage, EwErrorCode *errorCode)
 Get the value of a translated text. More...
 
BSTR getTag (EwErrorCode *errorCode)
 Get the mark of this object. More...
 
EwErrorCode setTag (BSTR strValue)
 Set the mark of this object. More...
 
BSTR getTagRoot (EwErrorCode *errorCode)
 Get the mark root of this object. More...
 
EwErrorCode setTagRoot (BSTR strValue)
 Set the mark root of this object. More...
 
EwTagMode getTagMode (EwErrorCode *errorCode)
 Get the mark mode of this object. More...
 
EwErrorCode setTagMode (EwTagMode eTagMode)
 Set the mark mode of this object. More...
 
long getTagNumber (EwErrorCode *errorCode)
 Get the mark number of this object. More...
 
EwErrorCode setTagNumber (long lValue)
 Set the mark number of this object. More...
 
EwErrorCode setNextTagNumber ()
 Set the next number to have a unique mark. More...
 
VARIANT_BOOL isTagUnique (EwErrorCode *errorCode)
 Returns true or false if mark is unique. More...
 
- Public Member Functions inherited from IEwObjectBaseX
EwErrorCode remove ()
 Remove the object from the current project. More...
 
EwErrorCode update ()
 Update the object inside the current project. More...
 
LONG getID ()
 

Detailed Description

Use this interface to manage a cable inside a project.

Since
2018 SP0

Member Function Documentation

◆ get3dDestination()

BSTR IEwProjectCableX::get3dDestination ( EwErrorCode errorCode)

Get the 3D Destination associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
3D Destination associated with the current cable.

◆ get3dOrigin()

BSTR IEwProjectCableX::get3dOrigin ( EwErrorCode errorCode)

Get the 3D Orign associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
3D Orign associated with the current cable.

◆ getAppliedVoltage()

DOUBLE IEwProjectCableX::getAppliedVoltage ( EwErrorCode errorCode)

Get the applied voltage associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
applied voltage associated with the current cable.

◆ getArticleNumber()

BSTR IEwProjectCableX::getArticleNumber ( EwErrorCode errorCode)

Get the article number.

Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_NO_ERROR No error detected
  • EW_UNDEFINED_ERROR if another error occurred
Returns
the string article number

◆ getCoreCount()

LONG IEwProjectCableX::getCoreCount ( EwErrorCode errorCode)

Get cable core count.

Since
2018 SP3
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_NO_ERROR No error detected
  • EW_INVALID_OBJECT Cable object invalid
Returns
Number of cable cores

◆ getExternalID()

BSTR IEwProjectCableX::getExternalID ( EwErrorCode errorCode)

Get external identifier of this cable.

Since
2019
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_NO_ERROR if no error detected
  • EW_UNDEFINED_ERROR if an error occurred
Returns
will contain the external identifier in this cable

◆ getFamily()

BSTR IEwProjectCableX::getFamily ( EwErrorCode errorCode)

Get the family associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
family associated with the current cable.

◆ getFullLoadCurrent()

DOUBLE IEwProjectCableX::getFullLoadCurrent ( EwErrorCode errorCode)

Get the full load current associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
applied voltage associated with the current cable.

◆ getHarnessID()

LONG IEwProjectCableX::getHarnessID ( EwErrorCode errorCode)

Get the Harness ID associated with the current cable.

Return -1 if the current cable is not associated to a harness.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_NO_ERROR No error detected
  • EW_INVALID_OBJECT current object is invalid
Returns
the Harness ID associated with the current cable.

◆ getLinearMass()

BSTR IEwProjectCableX::getLinearMass ( EwErrorCode errorCode)

Get the linear mass (density) of this cable.

Since
2020 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_NO_ERROR if no error detected
  • EW_UNDEFINED_ERROR if another error occurred
Returns
a string with linear mass (density) of this cable

◆ getManufacturer()

BSTR IEwProjectCableX::getManufacturer ( EwErrorCode errorCode)

Get the manufacturer of the cable.

Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_NO_ERROR No error detected
  • EW_UNDEFINED_ERROR if another error occurred
Returns
the string article number

◆ getReference()

BSTR IEwProjectCableX::getReference ( EwErrorCode errorCode)

Get the reference of the cable.

Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_NO_ERROR No error detected
  • EW_UNDEFINED_ERROR if another error occurred
Returns
the string article number

◆ getStandard()

BSTR IEwProjectCableX::getStandard ( EwErrorCode pErrorCode)

Get the standard associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
standard associated with the current cable.

◆ getStockNumber()

BSTR IEwProjectCableX::getStockNumber ( EwErrorCode errorCode)

Get the stock number associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
stock number associated with the current cable.

◆ getSupplierName()

BSTR IEwProjectCableX::getSupplierName ( EwErrorCode errorCode)

Get the supplier name associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
supplier name associated with the current cable.

◆ getVoltageDrop()

DOUBLE IEwProjectCableX::getVoltageDrop ( EwErrorCode errorCode)

Get the voltage drop associated with the current cable.

Since
2021 SP0
Parameters
[out]errorCodeEwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected
Returns
voltage drop associated with the current cable.

◆ set3dDestination()

EwErrorCode IEwProjectCableX::set3dDestination ( BSTR  str3dDestination)

Set the 3D Destination associated with the current cable.

Since
2021 SP0
Parameters
[in]str3dDestinationnew 3D destination.
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ set3dOrigin()

EwErrorCode IEwProjectCableX::set3dOrigin ( BSTR  str3dOrigin)

Set the 3D Orign associated with the current cable.

Since
2021 SP0
Parameters
[in]str3dOriginnew 3D origin
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ setAppliedVoltage()

EwErrorCode IEwProjectCableX::setAppliedVoltage ( DOUBLE  dAppliedVoltage)

Set the applied voltage associated with the current cable.

Since
2021 SP0
Parameters
[in]dAppliedVoltagenew applied voltage
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ setArticleNumber()

EwErrorCode IEwProjectCableX::setArticleNumber ( BSTR  strArticleNumber)

Set the article number.

Parameters
[in]strArticleNumberstring to set on the article number
Returns
EwErrorCode enum type, can be:
  • EW_NO_ERROR No error detected
  • EW_UNDEFINED_ERROR if another error occurred

◆ setCoreStubs()

EwErrorCode IEwProjectCableX::setCoreStubs ( LONG  nCoreIdx,
DOUBLE  dStubLengthFrom,
DOUBLE  dStubLengthTo 
)

Set lengths of cable core stubs.

Since
2018 SP3
Parameters
[in]nCoreIdxCable core index, starts with 0
[in]dStubLengthFromFROM stub length
[in]dStubLengthToTO stub length
Returns
errorCode EwErrorCode enum type, can be:
  • EW_NO_ERROR No error detected
  • EW_INVALID_OBJECT Cable object invalid
  • EW_OBJECT_NOT_FOUND if core index is out of range

◆ setExternalID()

EwErrorCode IEwProjectCableX::setExternalID ( BSTR  strExternalID)

Set the external identifier of this cable.

Since
2019
Parameters
[in]strExternalIDThe external identifier you want to set
Returns
EwErrorCode enum type, can be:
  • EW_NO_ERROR if no error detected
  • EW_UNDEFINED_ERROR if another error occurred

◆ setFamily()

EwErrorCode IEwProjectCableX::setFamily ( BSTR  strFamily)

Set the family associated with the current cable.

Since
2021 SP0
Parameters
[in]strFamilynew Family name
Returns
errorCode EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ setFullLoadCurrent()

EwErrorCode IEwProjectCableX::setFullLoadCurrent ( DOUBLE  dFullLoadCurrent)

Set the full load current associated with the current cable.

Since
2021 SP0
Parameters
[in]dFullLoadCurrentnew full load current
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ setHarnessID()

EwErrorCode IEwProjectCableX::setHarnessID ( long  lHarnessID)

Set the Harness ID of this cable.

Cable will be added to the harness after calling update or insert. Harness must exists to be able to set the ID. Setting the ID to -1 will remove the cable from the harness.

Since
2021 SP0
Parameters
[in]lHarnessIDThe Harness id to add.
Returns
EwErrorCode enum type, can be:
  • EW_NO_ERROR if no error detected
  • EW_BAD_INPUTS if the lHarnessID is invalid (not found or not -1)
  • EW_INVALID_OBJECT current object is invalid
  • EW_UNDEFINED_ERROR if another error occurred

◆ setInRushFactor()

EwErrorCode IEwProjectCableX::setInRushFactor ( DOUBLE  dInRushFactor)

Set the rush factor associated with the current cable.

Since
2021 SP0
Parameters
[in]dInRushFactornew rush factor
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ setLength()

EwErrorCode IEwProjectCableX::setLength ( DOUBLE  dLength)

◆ setLinearMass()

EwErrorCode IEwProjectCableX::setLinearMass ( BSTR  strLinearMass)

Set the linear mass (density) of this cable.

Since
2020
Parameters
[in]strLinearMassThe linear mass (density) you want to set
Returns
EwErrorCode enum type, can be:
  • EW_NO_ERROR if no error detected
  • EW_BAD_INPUTS if the length of value is greater than maximum length of the field or units are not allowed
  • EW_UNDEFINED_ERROR if another error occurred

◆ setStandard()

EwErrorCode IEwProjectCableX::setStandard ( BSTR  strStandard)

Set the standard associated with the current cable.

Since
2021 SP0
Parameters
[in]strStandardnew standard
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ setStockNumber()

EwErrorCode IEwProjectCableX::setStockNumber ( BSTR  strStockNumber)

Set the stock number associated with the current cable.

Since
2021 SP0
Parameters
[in]strStockNumbernew stock number
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ setSupplierName()

EwErrorCode IEwProjectCableX::setSupplierName ( BSTR  strSupplierName)

Set the supplier name associated with the current cable.

Since
2021 SP0
Parameters
[in]strSupplierNamenew Supplier name
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected

◆ setVoltageDrop()

EwErrorCode IEwProjectCableX::setVoltageDrop ( DOUBLE  dVoltageDrop)

Set the voltage drop associated with the current cable.

Since
2021 SP0
Parameters
[in]dVoltageDropnew Voltage
Returns
EwErrorCode enum type, can be:
  • EW_UNDEFINED_ERROR if another error occurred
  • EW_INVALID_OBJECT current object is invalid
  • EW_NO_ERROR No error detected


Provide feedback on this topic

SOLIDWORKS welcomes your feedback concerning the presentation, accuracy, and thoroughness of the documentation. Use the form below to send your comments and suggestions about this topic directly to our documentation team. The documentation team cannot answer technical support questions. Click here for information about technical support.

* Required

 
*Email:  
Subject:   Feedback on Help Topics
Page:   SOLIDWORKS Electrical API: IEwProjectCableX Interface Reference
*Comment:  
*   I acknowledge I have read and I hereby accept the privacy policy under which my Personal Data will be used by Dassault Systèmes

Print Topic

Select the scope of content to print:

x

We have detected you are using a browser version older than Internet Explorer 7. For optimized display, we suggest upgrading your browser to Internet Explorer 7 or newer.

 Never show this message again
x

Web Help Content Version: API Help (English only) 2021 SP05

To disable Web help from within SOLIDWORKS and use local help instead, click Help > Use SOLIDWORKS Web Help.

To report problems encountered with the Web help interface and search, contact your local support representative. To provide feedback on individual help topics, use the “Feedback on this topic” link on the individual topic page.