| Symbol | Check: The software checks to ensure the
							geometric characteristic and feature combination is valid. An error
							occurs if the combination is invalid, for example, if you apply
								Flatness when the toleranced
							feature is a Boss. | 
					
						| Tolerance Zone Shape | Filters: The
							software filters the options based on the selected geometric
							characteristic. For example, the options are enabled for Position tolerances and disabled for
								Circularity tolerances. Check: The software checks to
								ensure the tolerance zone and feature combination is valid. An error
								occurs if the combination is invalid, for example, if you apply a
								diameter symbol when the toleranced feature is a plane.  | 
					
						| Material Condition Modifier | Filters: The
							software filters the options based on the selected geometric
							characteristic. For example, the options are enabled for Position and disabled for Runout. Checks:  
								The software checks to ensure the maximum
									material condition (MMC) and least material condition (LMC)
									symbols are applied only when the toleranced feature is a
									feature of size. An error occurs when the feature is not a
									feature of size, for example, when the feature is a pocket. The software checks to ensure a size tolerance
									is applied to the toleranced feature when you specify MMC or
									LMC. An error occurs when a size tolerance does not exist.  | 
					
						| Projected Tolerance Zone | Filters: The
							software filters the options based on the selected geometric
							characteristic. For example, the options are enabled for Position and disabled for Concentricity. Checks:  
								The software checks to ensure the toleranced
									feature supports a projected tolerance zone. An error occurs if
									the feature does not. For example, if you apply a projected
									tolerance zone when the feature is a plane (ISO). The software checks to ensure the toleranced
									feature supports a projected tolerance zone. An error occurs if
									the feature does not. For example, if you apply a projected
									tolerance zone when the feature is a plane (ISO).  | 
					
						| Unit Basis Tolerance | Check: The
							software checks to ensure the format used for the per unit area or per
							unit length criteria is valid. An error occurs when the format is not
							recognized. | 
					
						| Tolerance 2 | Check: The
							software checks to ensure the format of the input, tolerance value
							followed by “MAX”, is valid. An error occurs when the format is not
							recognized. | 
					
						| Primary, Secondary, and Tertiary Datum | Filters: 
								The software filters the datum options based on
									the selected geometric characteristic. For example, the options
									are enabled for Position
									and disabled for Flatness. The software filters the options for the
									material condition modifiers based on the selected geometric
									characteristic. For example, the options are enabled for
										Position and disabled
									for Runout.  Checks:  
								The software checks to ensure the entered datum
									label is the label of an existing datum. An error occurs when it
									is not. The software checks to ensure MMC and LMC
									symbols are only applied when the datum feature is a feature of
									size. An error occurs when the feature is not a feature of size,
									for example, when the feature is a plane. The software checks to ensure the datums define a valid datum reference frame based on the rules specified by ASME Y14.5.1M. An error occurs for nonconforming datum sets, for example, if the primary and secondary datums are two parallel planes.  | 
					
						| Composite Frame | Check: When you specify datums, the
							software checks to ensure the datums specified in the lower tier are
							entered in the same order of precedence as the upper tier. An error
							occurs if the datums do not repeat, for example, if the primary datum in
							the upper tier is “A,” but “B” is entered as primary in the lower tier. |