As an
alternative to a full mold cooling analysis,
the
Mold Wall Temperature boundary condition
allows you to
define
a temperature field that varies over the surface of the cavity.
To open the Mold Wall
Temperature PropertyManager:
- In the PlasticsManager, right-click Boundary
Conditions, and click Mold Wall
Temperature
.
Settings
On the cavity surface, select individual faces, or a group of faces with a
bounding box to apply a mold temperature.
 |
Faces
|
Specifies faces on the cavity surface where you specify
the mold wall temperature. |
 |
Wall Temperature |
Defines the temperature of the mold for the selected
faces. |
For a more detailed consideration of mold temperature, you can perform a
COOL simulation that computes the heat
transfer between the cavity, mold, and cooling channels. These COOL simulation results provide temperatures that
vary both in location and over time. These results override any temperature values
you enter in the Fill Settings and Mold Wall Temperature PropertyManagers.
If you do not assign any mold wall temperature to surfaces as a boundary
condition, the value you define in applies a uniform mold temperature for the whole cavity surface. The
uniform mold temperature can also vary over time.