Terminal properties

|
Contextual menu of terminal: Symbol
properties |
The terminal edition is automatically displayed after insertion.
Associate with an existing mark
If you want to associate a Terminal strip or a terminal with an existing
mark, select it in the list on the right, or manually give it the same
mark and use the [= >] button
to create an association.
At the top of the dialog box, filters can help you find an existing
component.
For a multi-level terminal, you can associate only the level you want,
by selecting the circuit in the list.
Terminal Strip
Mark
The terminal strip mark is automatically calculated according to the
electrical project settings.
Mode: If you select the Automatic mode, the mark is automatically
calculate according to the configuration settings. If you select Manual mode, you must enter the
mark manually in the Mark setting.
Mark: Displays the automatic
mark or used to enter the manual mark.
Root: Displays the root associated
to the terminal strip depending on the terminal strip class.
Number: Displays the order number
assigned to the terminal strip. You can change this number but you cannot
use an existing number.
Permanent component: When the
last symbol representing the terminal strip is deleted, the terminal strip
is also deleted. If you check this box, the terminal strip is not deleted.
To delete a permanent terminal strip, use the command Delete
component in its contextual menu in the Components
tab (dockable panel).
Hierarchy
Class : Allows you to change
the terminal strip classification. This is used when you assign a manufacturer
part. It also allows you to define the root used during automatic marking.
Parent: Displays the name of
the main terminal strip which a child or sub component is dependent on.
Location / Function: During
symbol insertion, the location
(function) is automatically
taken from the drawing, or the location (function) outline if the symbol
was inserted inside one. You can assign a different location (function)
by clicking the button [...] and
selecting the location (function) you want.
Terminal
Mark
The terminal mark is automatically calculated according to the electrical
project settings.
Mode: If you select the Automatic mode, the mark is calculate
automatically according to the configuration settings. If you select Manual mode, you must enter the
mark manually in the Mark setting.
Mark: Displays the automatic
mark or used to enter the manual mark.
Root: Displays the root associated
to the terminal depending on the terminal class.
Number: Displays the order number
assigned to the terminal. You can change this number but you cannot use
an existing number.
Permanent component: When the
last symbol representing the terminal is deleted, the component is also
deleted. If you check this box, the terminal is not deleted.
To delete a permanent component, use the command Delete component in its contextual
menu in the Components
tab (dockable panel).
hierarchy
Class : Allows to change the
terminal classification. This is used when you assign a manufacturer part.
It also allows you to define the root used during automatic marking.
Parent: Displays the name of
the main component (terminal strip) which a child or sub component is
dependent on.
Location / Function: During
symbol insertion, the location
(function) is automatically
taken from the drawing, or the location (function) outline if the symbol
was inserted inside one. You can assign a different location (function)
by clicking the button [...] and
selecting the location (function) you want.
Manufacturer data
This data comes from the manufacturer part, but can be manually modified.
The data types are specified in the definition of the class.
Description
The first translatable data field of the component. You can enter a
description in all languages managed in the electrical project.
User data / Translatable data
The user data fields can
be used to enter all information that you would like to manage for the
component.