You increase the number of plies to 16 to improve the factor of safety of the composite T-joint.
To change the laminate layup for the shells:
-
In the Partial study tree,
right-click the vertical cylindrical shell SurfaceBody
2(Surface-Extrude2) and click Edit
Definition.
-
In the Shell Definition
PropertyManager:
-
Under Type,
select Composite.
-
Under Composite
Options:
- Set Total
Plies to 16.
- Select Symmetric.
-
Click
.
-
Repeat steps 1 through 3 for the horizontal cylindrical shell SurfaceBody 1(Surface-Trim1) to increase the number of plies to 16.
-
To run the study, click Run This
Study