Configuration-Specific Properties in Title Block Tables

When a part or assembly has multiple configurations, the title block table can display the property values of the active configuration.

If configuration-specific properties are not defined but custom properties are, the custom properties are displayed.

To link configuration-specific properties to title block table cells:

  1. Add a title block table to a part or assembly with multiple configurations.
  2. Double-click a cell you want to link to a configuration-specific property.
  3. Click Link to Property properties_link.png Button (Note Formatting toolbar).
  4. In the Link to Property dialog box, click Current document.
  5. Select the property to link to from the drop-down list.
    If the list does not contain the property you want, click File Properties and on the Configuration Specific tab, add a property.
  6. Click OK.
    The value is added to the cell.
  7. Repeat steps 2 through 6 to link configuration-specific values to other cells.
  8. In the ConfigurationManager, change to another configuration and repeat the procedure to add and link to property values that are specific to that configuration.