Symbol properties
The symbol properties dialog box is identical to the one used for schematic
and line diagram symbols.

|
Contextual menu of symbol: Symbol
properties |
The symbol properties dialog box opens automatically any time you insert
a symbol. You can also access the dialog box with the symbol Properties
command in the symbol contextual menu.
According to the selected symbol, several properties can be disabled.
If you select several symbols, only the common properties are enabled.
Associate with an existing mark
If you want to associate a symbol with an existing mark, select it in
the list on the right, or manually give it the same mark and use the [= >] button to create an association.
At the top of the dialog box, filters can help you find an existing
component.
Edit symbol
Mark
The symbol mark is automatically calculated according to the electrical
project settings.
Mode: If you select the Automatic mode, the mark is calculated
automatically according to the configuration settings. If you select Manual mode, you must enter the
mark manually in the Mark setting.
Mark: Displays the automatic
mark or used to enter the manual mark.
Root: Displays the root associated
with the symbol depending on the symbol class.
Number: Displays the order number
assigned to the symbol. You can change this number but you cannot use
an existing number.
Permanent component: When the
last symbol representing the component is deleted, the component is also
deleted. If you check this box, the component is not deleted.
To delete a permanent component, use the command Delete component in its contextual
menu in the Components
tab (dockable panel).
Hierarchy
Class: Allows you to change
the symbol classification. This is used when you assign a manufacturer
part. It also allows you to define the root used during automatic marking.
Parent: Displays the name of
the main component which a child or subcomponent is dependent on (such
as a PLC card and its rack).
Location / Function: During
symbol insertion, the location
(function) is automatically
taken from the drawing, or the location (function) outline if the symbol
was inserted inside one. You can assign a different location (function)
by clicking the button [...] and
selecting the location (function) you want.
Manufacturer data
This data comes from the manufacturer part, but can be manually modified.
The data types are specified in the definition of the class.
Description
The first translatable data field of the component. You can enter a
description in all languages managed in the electrical project.
User data / Translatable data
The user data fields can
be used to enter all information that you would like to manage for the
component.
Symbol data
Cross references type: Select
the cross references level for the symbol currently being edited. By default
the value displayed is that configured in the properties for the symbol
(see chapter: Symbol properties)
Terminal type: Allows you to
define the symbol of terminal type, associated with this symbol, that
can be used to generate the terminal strip drawings. To use this symbol,
you must activate the Insert custom symbol
parameter in the Terminal
strip drawing configuration.
Terminal strip symbol: Allows
you to define the terminal strip symbol, associated with this symbol,
that can be used to generate the terminal strip drawings. To use this
symbol, you must activate the Insert
custom symbol parameter in
the Terminal strip
drawing configuration