The cabling order optimization command works alongside the cabling order management
command. Its behavior is different depending on whether or not you have created a 2D cabinet
layout.
To access the Optimize wire cabling order, click
.
If you have created a 2D cabinet layout, cabling order optimization takes into
account the position of components inserted in the cabinet to limit the length of
the wires. If there is no 2D cabinet layout, optimization uses the position of
components in the scheme drawings.
Selection
Option |
Description |
Whole Project
|
Handles all the electrical project complex
equipotentials. |
Current Book
|
Handles the equipotentials present on the drawings of the book
that contains the current drawing. |
Wires selected in scheme
|
Only handles the equipotentials of the wires selected in the
drawing. |
Selected Locations
|
Opens the location selector to let you select the locations to
handle. |
Action
Option |
Description |
Remove manual wire cabling order
|
Removes and recalculates the manual cabling order (performed
manually by the user). |
Remove cable core association
|
Cabling order optimization does not handle wires representing
a cable core by default. Select this option to automatically
uncable the wires handled. |
Remove bridges
|
Cabling order optimization does not handle connections
representing bridges by default. Select this option to
automatically delete the bridges. |
Cabling Direction in 2D Cabinet Layout
Select the direction in which you want to optimize the cabling order from the 2D
cabinet layout.