Running the Static Studies

  1. Mesh the Ready-Pressure study: in the Simulation study tree, right-click Mesh part.png and select Create Mesh .
    1. Under Mesh Parameters, set Unit to in and Global Size to 1.80.
    2. Under Options, select Run (solve) the analysis.
    3. Click PM_OK.gif.
  2. Copy the mesh from the Ready-Pressure study to the Ready-Temperature, Partial-VerticalGravity, and Partial-HorizontalGravity studies.
  3. Run the three additional studies mentioned above.
    Copying the mesh saves time and ensures that you have the same mesh for all of the static studies.