Menu: Electrical project > Configurations > PLC drawing... > Properties

Menu: Electrical Project > Configurations > PLC drawing... > New

Dockable panel > Contextual menu of the electrical project: Configurations > PLC drawing... > Properties

Dockable panel > Contextual menu of the electrical project: Configurations > PLC drawing... > New

 

A PLC drawing configuration file groups all the PLC file layout settings. You can create as many configurations as you wish. The configurations are grouped in the PLC configuration management.

 

The PLC module drawing configuration dialog box is divided into two parts. The right-hand part illustrates the settings displayed in the left-hand part. When you select a setting, the graphics display the correspondence in red.

Several tabs group the settings by theme.

General

Name: The name of the configuration file.

Description: Enter a description in all languages supported by the software.

Size

General

All numeric values use the unit system set in the electrical project configuration.

Orientation: Select the direction of the module drawing. In Vertical mode, the module can be inserted on the right or the left of the drawing.

Size

Module width: Enter the width of the module.

 

Maximal height of a symbol in a drawing: Enter the height of the module.

Channels

Channel separator width: Enter the width of the vertical line separating 2 PLC channels.

Channel height: Enter the height of the channel.

Combs

Comb width: The comb is the graphic element grouping channels. Enter the distance between the left of the module and the vertical line of the comb (E).

Comb tooth width: Enter the width of the horizontal line of the comb (F).

Attributes

This tab allows you to manage the location of the attributes to be inserted; these attributes can also be edited.

 

Opens the symbol selector to select the desired symbol.

Removes the symbol.

Opens the symbol editor to modify it.

Information (Top)

Y coordinate: Enter the distance between the horizontal line of the module and the insertion point of attributes.
These attributes have a right justification (A).

X for left symbol: Enter the distance between the vertical line of the module and the insertion point of attributes for a module symbol inserted on the left of the drawing (B).

X for right symbol: Enter the distance between the vertical line of the module and the insertion point of attributes for a module symbol inserted on the right of the drawing (C).

Information (Bottom)

Y coordinate: Enter the distance between the horizontal line of the module and the insertion point of attributes.
These attributes have a left justification (D).

X for left symbol: Enter the distance between the vertical line of the module and the insertion point of attributes for a module symbol inserted on the left of the drawing (E).

X for right symbol: Enter the distance between the vertical line of the module and the insertion point of attributes for a module symbol inserted on the right of the drawing (F).

 

Layout

Allows you to manage the PLC module drawing layout settings.

Settings in the General section are available only for vertical drawings of the module (set on the Size tab).

General

Options: (Available only for vertical representation) You can draw one or more modules per drawing. Select the option you want.

Column size: If you select One symbol per column in the previous parameter, enter the size of the column. The preview displays a vertical line to show this value.

Symbol insertion point

Y coordinate: Enter the Y coordinate corresponding to the insertion point of the module (A).

X for left symbol: Enter the X coordinate corresponding to the insertion point of the module when the module is drawn on the left of the drawing (B).

X for right symbol: Enter the X coordinate corresponding to the insertion point of the module when the module is drawn on the right of the drawing (C).

Connection points

Allows you to define the symbol used to propagate the terminal number. This symbol must contain the attribute #P_TAG_0.

 

Opens the symbol selector to select the desired symbol.

Removes the symbol.

Opens the symbol editor to modify it.

Circuits

These settings allow you to define symbols and macros associated with a type of circuit for a graphical representation on the left or the right of the drawing.

Circuit type / Direction: These settings allow you to define the direction in which the module is drawn (insertion in the left or right part of the drawing). SOLIDWORKS Electrical examines the module circuits in the order that they appear in the PLC management. The module circuit is compared with the circuits in the configuration list. As soon as the circuits match, SOLIDWORKS Electrical saves the setting you have selected (Undefined, Left or Right) and uses it to insert the module. If you choose Undefined for a circuit, SOLIDWORKS Electrical will move on to the next circuit until it finds a circuit for which the Left or Right mode has been selected.

Example 1:

The first circuit for the module is Digital output. If you select Digital PLC output in the configuration list and you select Right mode, the module will be inserted in the right part of the drawing.

Example 2:

The first circuit for the module is Power supply. It is not possible to tell from this type of circuit if the module will be inserted in the Left or Right part of the drawing. You must therefore select the Undefined mode for Power type circuits. SOLIDWORKS Electrical will therefore move on to the next circuit until it meets a circuit for which you have selected Left or Right mode.

Delete circuit type association: This button allows you not to allocate a symbol or macro to the circuit, or to delete the existing associations.

PLC channel pattern symbols: Allows you to select the symbols representing the inside of the module for insertion into the Left or Right part of the drawing. These settings are associated with the circuit selected in the list.

Macro connected to channels: in addition to automatic generation of the module drawing, SOLIDWORKS Electrical allows you to automatically generate the diagram connected to the module for insertion in the Left or Right part of the drawing. A macro can be associated with each type of circuit.

File data

This tab allows you to define the parameters for the automatic generation of information to be transferred to the properties of PLC drawing. Clicking the column allows you to open the Formula management.

Description: Allows you to define the parameters for the automatic generation of data to be transferred to the description of the PLC drawing.

User data/Translatable data: Allows you to set the parameters for the automatic generation of data to be transferred to the user data of the PLC drawing.



Provide feedback on this topic

SOLIDWORKS welcomes your feedback concerning the presentation, accuracy, and thoroughness of the documentation. Use the form below to send your comments and suggestions about this topic directly to our documentation team. The documentation team cannot answer technical support questions. Click here for information about technical support.

* Required

 
*Email:  
Subject:   Feedback on Help Topics
Page:   PLC design Configuration (ANSI)
*Comment:  
*   I acknowledge I have read and I hereby accept the privacy policy under which my Personal Data will be used by Dassault Systèmes

Print Topic

Select the scope of content to print:




x

We have detected you are using a browser version older than Internet Explorer 7. For optimized display, we suggest upgrading your browser to Internet Explorer 7 or newer.

 Never show this message again
x

Web Help Content Version: SOLIDWORKS Electrical 2022 SP05

To disable Web help from within SOLIDWORKS and use local help instead, click Help > Use SOLIDWORKS Web Help.

To report problems encountered with the Web help interface and search, contact your local support representative. To provide feedback on individual help topics, use the “Feedback on this topic” link on the individual topic page.