Applying Loads to the Assembly You now apply pressure loads to the roof and a side vertical glass panel. The study predefines a gravity load representing the weight of the assembly. Click the down arrow on External Loads Advisor (Simulation CommandManager) and select Pressure . In the PropertyManager, on the Type tab under Type, select Normal to selected face. In the graphics area, select the face of the roof for Faces for Pressure . Under Pressure Value, in Unit select psi, then for Pressure Value type 0.625. Click . Repeat steps 1 through 5 to define a wind load (pressure) of 0.15 psi on the face of the vertical glass panel as shown. Parent topicDesign Check for a Mixed Mesh Assembly Previous topic Global Contact Condition for Touching Entities Next topic Meshing the Assembly and Running the Study